Holtkamp Electronics UNO 7600XL engl. techn. Stand 04.2016 4050_04.2016 V09.2019
- 17 -
Display shows
Factory setting
Description
Short time sale
no
The short time sale offers the possibility for activation a partial main time sale
per coin insert. The sale of partial main time takes place with insert of the first
coin.
● If "yes" is set, the short time sale is activated.
● If "no" is set, the short time sale is deactivated.
The program of UNO makes sure, that only the minimum insert or the
short time sale can be activated. If will be still tries, to activated both
positions, the position, which will be activated at last, is active, the other
will be adjusted automatically on "no".
If will be neither adjusted the minimum insert or the short time sale, the full
price must be paid for the adjusted main time. The same is true for buy in ad
-
dition for time. If so bought the main time at once, the full price must be paid
again for purchase further time.
HQL time
yes
The HQL time offers the possibility to hinder the new start of a main time,
during the run-out time. The new main time can be paid yet during the run-out
time.
The pre-run time of the new purchased main time will be cleared with the
remaining run-out time at the time of payment. If this function is not activated,
the run-out time does not matter, the main time starts after end of the pre-run
time. If the forced remote start activated (forced remote start active, if pre-run
time = "0"), the device starts only at the end of run-out time with remote start
button.
● If "yes" is set, the HQL time is activated.
● If "no" is set, the HQL time is deactivated.
Purchase lock
by OR
no
The purchase lock by run-out offers the possibility to block the buying of main
time during the run-out time. By activating this option the coin insert are blo
-
cked during the run-out time. Buying time during run-out time is impossible.
● If “yes” is set, the purchase lock by run-out is activated.
● If “no” is set, the purchase lock by run-out is deactivated.
Pre-run relay
no
The pre-run relay offers the possibility to switch the fan on at the beginning of
the pre-run time. They remain switched on until run-out time is ended. When
the pre-run time is set to 0, the fan will start by activating the remote start and
stays on until the end of the run-out time.
● If “yes” is set, the pre-run relay is activated.
● If “no” is set, the pre-run relay is deactivated.
Summary of Contents for UNO 7600/XL
Page 1: ...Operating instruction UNO Coin timer ...
Page 32: ...Holtkamp Electronics UNO 7600XL engl techn Stand 04 2016 4050_04 2016 V09 2019 32 ...
Page 34: ...Holtkamp Electronics UNO 7600XL engl techn Stand 04 2016 4050_04 2016 V09 2019 34 ...
Page 35: ...Holtkamp Electronics UNO 7600XL engl techn Stand 04 2016 4050_04 2016 V09 2019 35 ...