ASSEMBLY
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
23
ABS 3000SE / ABS 5000SE
12
ASSEMBLY
12.1
Delivery content
Please check the product contents immediately after receipt for any eventual transport damage or
missing parts. Claims from transport damage or missing parts must be placed immediately after
initial machine receipt and unpacking before putting the machine into operation. Please
understand that later claims cannot be accepted anymore.
12.2
Workplace requirements
The workplace has to fulfill the requirements.
The ground has to be even, in level and hard. It must be suitable at least to weight it with double
weight per square meter than the machines net weight.
The chosen workplace must have access to a suitable electric supply net hat complies with the
machines requirements.
12.3
Power supply
A T T E N T I O N
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The mains supply must be secured with 16A:
3.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or
re-new it!
4.
The grounding wire should be held in green-yellow.
5.
Check, whether the feeding voltage and the Hz comply to the required values of the
machine. A deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working
voltage of 380V can work within a voltage bandwidth of 370 till 400V.
6.
After connecting, check the right running direction!
7.
Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
8.
A damaged cable must be replaced immediately
N O T I C E
Operation is only allowed with safety switch against stray current
(RCD max. stray current of 30mA)
Plug 400V:
5-wire:
with
N-conductor
4-wire:
without
N-conductor
Summary of Contents for ABS 3000SE
Page 57: ......