HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
Strana 40
DLABAČKA–MORTISING MACHINE-TALADRO HORIZONTAL-PERCEUSE HORIZONTALE- WIERTARKO - FREZARKA LBM 250C
16
TROUBLE SHOOTING
BEFORE YOU START WORKING FOR THE ELIMINATION OF DEFECTS, DISCONNECT THE
MACHINE FROM THE POWER SUPPLY.
Trouble
Possible cause
Solution
The magnetic support has
no magnetic force
•
Switch defective
•
Repair switch
•
Power supply is off
•
Repair power supply
•
Fuse is defectivet
•
Change fuse
•
Electric contactor is defective
•
Repair or change electric
contactor
The machine stops during
the work
•
One or more phases of the current
missing.
•
Check if all 3 phases are live
•
Machine overloading
•
Do not overload the machine
•
Thermal contact of the machine is
switched off
•
Wait for the motor to cool down
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY
CONNECTION TO THE ELECTRICITY GRID.
N O T I C E
Should you in necessary repairs not able to properly to perform or you have
not the prescribed training for it always attract a workshop to fix the
problem.