ASSEMBLY AND OPERATION
HOLZMANN Maschinen Austria www.holzmann-maschinen.at
Seite 30
Schweißgerät/ welding machine MSA250
12.4
6. Explanation of installation
Check the products according to the packing list when open the package.
Grounded protection.Attached the diagram 6
The power source is 400Vac/(50~60Hz) .The yellow/green double cable is grounding
cable.Be sure to connect the yellow/green double cable into the grounding connection
in the welding locale .Another way is selecting the M8 bolt on the back on the machine
and connect the grounding as the diagram Attached the diagram 7
confirm the positive and negative marks and install the cable as diagram.
Insert the connectors inside the positive "+" and negative "-" position and roll it in 90.
Do it oppositely when unloading the connectors. keep the surface clean
Install the welding gun on the wire feeder and roll the welding gun in 90,then
lock the
bolt.
If you use the CO2 heater, connected the heating power with 36V/3A power source.
Connect the gas pipe with the gas bottle according to the locale conditions. Check the
air proof conditions to ensure the good airproof.
Connect the control cable to the wire feeder with the relative connector of the power