12
SAA 901 | Version 1.01
Installation of the Chip Extraction Unit
Step 6: Insert the dust bag hook (1) into the hole for the
dust bag hook (14) on the plastic housing (13)
and attach the dust bag (2) to the dust bag
hook (Fig.9).
Fig. 9: Mounting Dust bag
Step 7: Place the dust bag (2) over the top opening of
the plastic housing (13) so that it completely
surrounds the opening and secure it with the
quick - release device (5) Fig.10).
Fig. 10: Quick clamp device
Step 8: Pull the catch (6) over the lower opening of the
plastic housing (13) so that it completely
closes the opening and secure it with the
quick - release device (3) Fig. 11.
Fig. 11: Quick clamp device Dustbag
Step 9: Insert a hose attachment (A) over the suction
hose (11) as far as it will go against the suction
connection of the appliance and secure it with
the hose clamp (A) as shown in Fig. 12.
Fig. 12: Hose mounting
Step 8: If devices with a suction connection diameter
of 100mm are to be connected to the ex-
traction system, lead a hose attachment (A)
over the suction hose (11). Now insert the con-
nection adapter (18) into the suction hose (11)
as far as it will go and secure it by tightening
the hose attachment (A).
Fig. 13: Connection Adapter