background image

18 | ENGLISH

Inspecting and replacing these parts is performed by the 

manufacturer during the general overhaul or by specially 

trained personnel.

7.3. Spare Parts

In order to obtain spare parts, identify the required parts 

and contact authorized HOMA customer service with your 

order. Authentic HOMA parts shall be used to maintain 

warranty.

Explosion Proof pumps must be identified as such, 
and the pump serial number must be referenced for 
proper parts identification.

Les pompes antidéflagrantes doivent être identifiées 
comme telles et le numéro de série de la pompe doit 
être mentionné pour une identification correcte des 
pièces.

8. Shutdown

8.1. Temporary  shutdown

For this type of shutdown, the machine remains installed 

and is not cut off from the electricity supply. For tempo-

rary shutdown, the machine must remain completely sub-

merged so that it is protected from frost and ice. Make 

sure the wet well and the pumped fluid cannot be covered 

by ice. This ensures that the machine is always ready for 

operation. Carry out a monthly start-up and run the pump 

in operating conditions for 5 minutes.

Caution!
Only test the pump under the proper conditions of op-
eration and use. Never run the machine dry. This can 
result in irreparable damage! 

Mise en guarde !
Ne tester la pompe que dans les conditions de 
fonctionnement et d’utilisation appropriées. Ne ja-
mais faire fonctionner la machine à sec. Cela peut 
entraîner des dommages irréparables !

8.2. Final shutdown / storage

Switch off the system, disconnect the machine from the 

electricity supply and dismantle and store it. Note the fol-

lowing information concerning storage:

Beware of hot parts!
When removing the machine, be careful of the tem-
perature of the housing components. These can heat 
up to well above 104°F. Let the machine cool down to 
ambient temperature before you touch it.

Attention aux composants chauds !
Lors du démontage de la machine, faire attention 
à la température des composants du boîtier. Ces 
appareils peuvent atteindre une température bien 
supérieure à 40°C. Laisser la machine refroidir à la 
température ambiante avant de la toucher

•  Clean the machine.

•  Store it in a clean, dry place, protect the machine 

against frost.

•  Place it down vertically onto a firm foundation and se-

cure it against falling.

•  Support the cable at the cable entry assembly to help 

avoid a permanent deformation.

•  Protect the ends of the electric power cable from 

moisture.

•  Protect the machine from direct sunshine as a pre-

ventive measure against brittleness in elastomer 

parts and the impeller and casing coating.

•  When storing the machine in a shop please remem-

ber: Radiation and gases which occur during electric 

welding destroy the elastomers of the seals.

•  During lengthy periods of storage, regularly (for ex-

ample every six months) turn the impeller or propeller 

by hand. This prevents indentations in the bearings 

and stops the rotor from rusting up.

8.3. Restarting after an extended period of storage

Before restarting the pump, it should be completely re-

commissioned. Clean it of dust and oil deposits, then car-

ry out the necessary maintenance actions (see “Mainte-

nance”). Check that the mechanical shaft seal is in good 

order and working properly. Once this work has been 

completed, the machine can be installed (see “Installa-

tion”) and connected to the electricity supply by a special-

ist. See “Start-up” for instructions on restarting.

Only restart the machine if it is in perfect condition and 

ready for operation.

Summary of Contents for TP30-70

Page 1: ...Installation Operation and Maintenance Manual TP30 70 Version 11 2021 ...

Page 2: ...very 08 4 2 Transport 08 4 3 Storage 09 4 4 Returning to the supplier 09 5 Installation and initial commissioning 10 5 1 General 10 5 2 Installation 11 5 3 Use of chains 12 5 4 Initial operation 12 5 5 Preparatory work 12 5 6 Electrical 12 5 7 Direction of rotation 14 5 8 Motor protection 14 5 9 Variable Frequency Drives 14 5 10 Types of startups 14 6 Maintenance 15 6 1 General 15 6 2 Maintenance ...

Page 3: ...ely or in part or used for any other purpose without the expressed consent of the man ufacturer 1 5 Technical terms Various technical terms are used in this operating and maintenance manual Dry run The product is running at full speed however there is no liquid to be pumped A dry run is to be strictly avoided If necessary a safety device must be installed wet installation type This installation ty...

Page 4: ...ey should be expressly marked as fastening devices Otherwise they should be carefully stored Mobile working equipment for lifting loads should be used in a manner that ensures the stability of the working apparatus during operation When using mobile working equipment for lifting non guided loads measures should be taken to avoid tipping and sliding etc Measures should be taken that no person is ev...

Page 5: ...he owner All per sonnel are responsible for ensuring that regulations are observed Certain parts such as the rotor and impeller rotate during operation in order to pump the fluid Certain materials can cause very sharp edges on these parts Beware of rotating parts The moving parts can crush and sever limbs Never reach into the pump unit or the moving parts during operation Switch off the machine an...

Page 6: ... density viscosity or the general composition change this can also alter many parameters of the product Different materials and impeller shapes are required for different pumped fluids The more exact your specifications on your order the more exactly we can modify our product to meet your requirements If the area of application and or the pumped fluid change we will be happy to offer supportive ad...

Page 7: ...of the stator and shaft with impeller assembly The cable for the power supply is de signed for maximum mechanical performance in accor dance with the characteristic or pump name plate Both the cable entries and the line are water pressure tight to the depth provided on the name plate The shaft bearing assembly is supported via robust maintenance free and permanently lubricated roller bearings All ...

Page 8: ... sealing cavity containing white mineral oil Oil condition may be monitored using the inspection plug on the bear ing housing and optional electronic monitoring 3 3 5 Volute The pump may be equipped with a stationary wear ring which can be found in the intake port This wear ring deter mines the gap between the impeller and the intake port If this gap is too big the performance of the pump decreas ...

Page 9: ...er les extrémités des câbles dans le fluide pompé ou dans d autres liquides The machine must be protected from direct sun light heat dust and frost Heat and frost can cause considerable damage to impellers rotors and coat ings The impeller must be turned at monthly intervals This prevents the bearing from locking and the film of lubricant on the mechanical shaft seal is renewed This also prevents ...

Page 10: ...edium which can lead to unfavorable operating conditions and result in increased wear Do not install more than one check valve into any pip ing system or problems will occur No Description 1 Pipe 2 Coupling system 3 Wet well 4 Inlet 5 Baffle plate 6 min liquid level 7 Pump External Seal Probe Installation Procedure If provided Mechanical Seal Leak Detection probe has been shipped loose to protect ...

Page 11: ...ob where necessary Check the correct installation dimensions of the pump s see dimensional drawings in the appendix Drill mounting holes for the guide rail bracket on the inside edge of the shaft opening If this is not possi ble due to the space available the guide rail bracket can also be mounted in an offset position with a 90 folded plate on the underside of the shaft cover Pro visionally faste...

Page 12: ...tial operation may only be carried out by qual ified and trained personnel accompanied by an au thorized HOMA representative following the safety instructions All staff working on the machine must receive read and understand the instructions Activate all safety devices and emergency stop switches before initial operation Electrical and mechanical adjustments may only be performed by professionals ...

Page 13: ...tems utilize two separate conductors for each leg of the circuit With either system the seal probe leads must be wired into a control circuit provided in the control panel This control circuit must energize the probe with a regulated power source and sense the closed circuit in event of wa ter intrusion Indication and alarm functions must also be provided in the control circuit Please see control ...

Page 14: ...ems often occur we recommend the additional use of protective devices e g overvoltage protection or under voltage pro tection or phase failure relays lightning protection etc When connecting the machine the local and legal require ments must be adhered to 5 9 Variable Frequency Drives Special considerations must be taken when operating pumps with variable frequency drives inverters The in verter c...

Page 15: ... machine After work ing on the machine all cleaning materials and tools should be removed from it All materials and tools should be stored in an appropriate place Operating supplies such as oil and lubricants must be collected in appropriate vessels and proper ly disposed Appropriate protective clothing is to be worn for cleaning and maintenance jobs Only lubricants expressly recommended by the ma...

Page 16: ...This may be the result of defective shaft seals In this case the condition of the shaft seals should be checked by a HOMA Service shop Oil type Mineral Oil Used oil has to be disposed according to the existing envi ronmental rules and regulations Functional inspection of safety and control devices Monitoring devices are temperature sensors in the motor oil chamber monitors motor protection relays ...

Page 17: ...es stated are for clean lubricated screws Fixing torque ft lbs for screws A2 A4 Coefficient of friction 0 2 A2 A4 Hardeness class 70 A2 A4 Hardeness class 80 DIN912 DIN933 DIN912 DIN933 M6 5 ft lbs 9 ft lbs M8 12 5 ft lbs 21 ft lbs M10 24 ft lbs 43 ft lbs M12 42 ft lbs 73 5 ft lbs M16 103 ft lbs 180 5 ft lbs M20 201 5 ft lbs 364 5 ft lbs 7 2 Changing the impeller and volute Changing the impeller a...

Page 18: ...re of hot parts When removing the machine be careful of the tem perature of the housing components These can heat up to well above 104 F Let the machine cool down to ambient temperature before you touch it Attention aux composants chauds Lors du démontage de la machine faire attention à la température des composants du boîtier Ces appareils peuvent atteindre une température bien supérieure à 40 C ...

Page 19: ...sures de sécurité appropriées Demandez toujours à une deuxième personne de s assurer que la machine est éteinte en cas d urgence Attachez les pièces mobiles pour éviter les blessures Toute intervention indépendante sur la machine se fait à ses propres risques et libère le fabricant de toute obligation au titre de la garantie The machine will not start Cause Solution Electricity supply interrupted ...

Page 20: ...fective parts Inadmissible levels of gas in the pumped liquid Contact the factory Two phase operation Have a specialist inspect the connection and correct it as necessary The machine does not run smoothly and is noisy Cause Solution Machine is running in an impermissible operation range Check the operational data of the machine and correct if necessary and or ad just the operating conditions The s...

Page 21: ... of the pump agitator it may be that no separate control cable is used In this case monitoring devices are run from the power cable Cable identification Motor Monitoring system Monitoring in winding T1 T2 Temperature limiter 2 switches in series T1 T4 Temperature controller 2 switches in series T1 T2 T3 Temperature limiter and controller K1 K2 PTC Thermistor 3 thermistors in series PT1 PT2 3 x PT1...

Page 22: ...22 ENGLISH Notizen Notes ...

Page 23: ...ENGLISH 23 ...

Page 24: ...HOMA Pump Technology 390 Birmingham Blvd Ansonia CT 06401 Phone 203 736 8890 Fax 203 736 8899 e Mail info homapump com Internet www homapump com Version 11 2021 ...

Reviews: