INSTALLATION 

 
NOTE: This unit has protection against static discharge in normal operation.  However, use static 
discharge precautions during installation.  Always touch the enclosure to discharge static before 
touching the connections. 
 
NOTE:  Do not make changes to terminal lock connections (TB1 – TB6) with power on!  Disconnect 
power 

AND

 batteries first. 

 

1.  GROUNDING 
 

Each Touchscreen Hub MUST be grounded to the controller.

  The HAI controller and HAI 

Touchscreen Hub(s) must be grounded together to prevent any current from flowing through the  
RS-485 data bus (connections A and B).  If not grounded properly, damage could occur to the HAI 
controller, HAI Touchscreen Hub, and/or OmniTouch touchscreens.  
 
Connect the “GND” terminal on the HAI Touchscreen Hub under the section marked 
“CONTROLLER”, to one of the “GND” terminals on the HAI controller. 
 

 
2.  COMMUNICATIONS CONNECTIONS 

 
Connect the terminals labeled “A” and “B” on the HAI Touchscreen Hub under the section marked 
“CONTROLLER”, to the “A” and “B” terminals on the HAI controller.   
 

Note:

 When connecting to an OmniLT, the terminal labeled “A” on the Touchscreen Hub connects to 

the “YEL” terminal and the terminal labeled “B” on the Touchscreen Hub connects to the ”GRN” 
terminal under the section marked “CONSOLE” on the OmniLT controller. 
 
The HAI Touchscreen Hub may be located in a remote location up to 800 feet from the HAI controller.   
 

 

Summary of Contents for 32A30

Page 1: ...HOME AUTOMATION INC Model 32A30 Touchscreen Hub Installation Manual Document Number 32I30 1 Rev B March 2008...

Page 2: ...Copyright 2005 2008 Home Automation Inc All Rights Reserved...

Page 3: ...installation the HAI Touchscreen Hub automatically sequences the startup of touchscreens and has a low voltage cut out feature for long term reliability and zero maintenance GENERAL The HAI Touchscree...

Page 4: ...grounded properly damage could occur to the HAI controller HAI Touchscreen Hub and or OmniTouch touchscreens Connect the GND terminal on the HAI Touchscreen Hub under the section marked CONTROLLER to...

Page 5: ...OWER 1 5A MAXIMUM ZONE ZONE HAI CONTROLLER GND GROUND B GREEN A YELLOW GND MUST BE CONNECTED TO GND ON HAI CONTROLLER CAT 5 CONNECTORS OMNITOUCH 5 7 53A00 1 OMNITOUCH WITH VIDEO 32A00 5 TERMINAL BLOCK...

Page 6: ...ve a maximum of 2 touchscreens connected in it OmniTouch 5 7 53A00 1 and OmniTouch with video 32A00 5 are connected to the Category 5 connectors OmniTouch 32A00 1 is connected to the terminal block re...

Page 7: ...used such as Cat 5 cable it is possible to connect multiple conductors together to achieve greater distance For example using only one of the 24 gauge conductor in the Cat 5 cable for power 1 for posi...

Page 8: ...e HAI Home Control for Windows Media Center for viewing and recording and or directly to television sets video recorders etc Using the on board RCA connectors connect camera outputs marked J10 Camera...

Page 9: ...or jumper J21 J26 from the first Touchscreen Hub 7 INSTALLING THE 32A32 2 HAI VIDEO ENCODER If you have purchased the HAI Video Encoder separately from the Touchscreen Hub install the Video Encoder as...

Page 10: ...32A32 2 VIDEO ENCODER NYLON SPACER 32A30 1 2 3 4 TOUCHSCREEN HUB...

Page 11: ...ect the BLACK battery wire to the minus terminal on the battery and connect the RED battery wire to the plus terminal on the battery DO NOT reverse the connections the battery fuse will blow Note that...

Page 12: ...19VDC 3 79 Amps Max 72W Input 120VAC 1 8A amps 60Hz Maximum Power 72 Watts Batteries Sealed Rechargeable 12 volts 4 8 amp hours each Low Voltage Cut Out 10VDC Main Fuse 5A Polyfuse Battery Fuses 5A Po...

Reviews: