INSTALATION & ASSEMBLY (cont.):
11.Using the provided Wire Nuts (#9), make the following wire connections
(Fig.
6)
:
White Extension Wire (#7)
to
White
(Neutral)
Supply Wire (#33)
Black Extension Wire (#8)
to
Black
(Hot)
Supply Wire (#34)
Fixture Ground Wire (#15)
to
Supply Ground Wire (#35)
12.Wrap all wire connections with electrical tape for a more secure connection.
Note: If you have electrical questions, consult your local electrical code for
approved grounding methods.
Page 9
Fig. 6
15. Fixture Ground Wire
8. Black Extension Wire
9. Wire Nut
35. Supply Ground Wire
7. White Extension Wire
34. Black (Hot) Supply Wire
33. White (Neutral) Supply Wire