background image

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 13

Care and Cleaning ............................................................. 14

Troubleshooting ................................................................. 14

1. 

To reduce the risk of electric shock, ensure the electricity has been 

turned off at the circuit breaker or fuse box before you begin.

2. 

All wiring must be in accordance with the National Electrical Code 

ANSI/NFPA 70 and local electrical codes. Electrical installation 

should be performed by a qualified licensed electrician.

3. 

The outlet box and support structure must be securely mounted 

and capable of reliably supporting 35 lbs. (15.9 kg). Use only UL 

Listed outlet boxes marked ”Acceptable for Fan Support of 35 lbs. 

(15.9 kg) or less”.

4. 

The fan must be mounted with a minimum of 7 ft. (2.1 m) clearance 

from the trailing edge of the blades to the floor.

5. 

Do not operate the reversing switch while the fan blades are in 

motion. You must turn the fan off and stop the blades before you 

reverse the blade direction.

6. 

Do not place objects in the path of the blades.

7. 

To avoid personal injury or damage to the fan and other items, use 

caution when working around or cleaning the fan.

8. 

Electrical diagrams are for reference only. Light kits that are not 

packed with the fan must be UL-listed and marked suitable for use 

with the model fan you are installing. Switches must be UL General 

Use Switches. Refer to the instructions packaged with the light kits 

and switches for proper assembly.

9. 

After making electrical connections, spliced conductors should be 

turned upward and pushed carefully up into the outlet box. The 

wires should be spread apart with the grounded conductor and the 

equipment-grounding conductor on one side of the outlet box.

10. 

All setscrews must be checked and retightened where 

necessary before installation.

WARNING:

 To reduce the risk of personal injury,

do not bend the blade brackets (also referred to as

flanges) during assembly or after installation. Do not

insert objects in the path of the blades.

WARNING:

 Suitable for use with solid-state speed 

controls.

WARNING:

 To avoid possible electrical shock,

turn the electricity off at the main fuse box before

wiring. If you feel you do not have enough electrical

wiring knowledge or experience, contact a licensed 

electrician.

WARNING:

 Electrical diagrams are for reference

only. Optional use of any light kit shall be UL-listed

and marked suitable for use with this fan.

WARNING:

 To reduce the risk of fire or electric

shock, “this fan should only be used with fan speed 

control part no. AP-3RDL manufactured by Dawnsun.

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury,

use only the screws provided with the outlet box.

READ AND SAVE THESE INSTRUCTIONS.

CAUTION:

 Changes or modifications not expressly 

approved by the party responsible for compliance 

could void the user’s authority to operate the 

equipment.

CAUTION:

 Do NOT use this fan with a dimmer switch 

or wall control. Using a dimmer switch or wall control 

will damage the fan.

WARNING:

 To reduce the risk of electric shock, this 

fan must be installed with an isolating wall switch.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation.      

Summary of Contents for 52-VEND

Page 1: ...ty products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Home Decorators Collection Item XXXX XXX XXX Model 51880 51884 51888 UL Model 52 VEND VENDOME 52 INCH CEILING FAN To view an instructional video on how to install this product 1 Go to www homedepot com and enter either the Item or Model number ...

Page 2: ...al wiring knowledge or experience contact a licensed electrician WARNING Electrical diagrams are for reference only Optional use of any light kit shall be UL listed and marked suitable for use with this fan WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed control part no AP 3RDL manufactured by Dawnsun Safety Information Table of Contents CAUTION To ...

Page 3: ...ns shall render the warranty invalid There is no other express warranty Home Decorators Collection hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some sta...

Page 4: ...allation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size AA BB CC Part Description Quantity AA Blade attachment screws BB Plastic wire connecting nut 3 CC Extra outlet box mounting screws 10 32 2 ...

Page 5: ... 1 Part Description Quantity F Blade 5 G Light kit pan 1 H Light kit fitter assembly 1 I Crystal shade 1 J Receiver 1 K Remote control battery included 1 L Extension lead wire 1 M LED bulb 6 5 Watt Max 2 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation conti...

Page 6: ...Use the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy C touches the ball downrod assembly B then remove the decorative canopy bottom cover and turn the canopy C 180 before attaching th...

Page 7: ...cket A and turn the canopy counterclockwise to remove the mounting bracket A from canopy C Assembling the fan Loosen but do not remove the setscrew GG on the collar II on top of the fan motor assembly E Install the downrod B by inserting it into the motor collar II and turning it clockwise until it is tight Re tighten the setscrew GG on the collar II on top of the fan motor assembly E 3 NOTE This ...

Page 8: ...g bracket A Seat the hanger ball portion of the ball downrod assembly B in the mounting bracket socket Ensure that the tab on the slide on mounting bracket A socket is properly seated in the groove in the hanger ball 1 2 WARNING To reduce the risk of fire electric shock or other personal injury mount the fan to an outlet box or supporting system marked Acceptable for fan support of 35 lbs 15 9 kg ...

Page 9: ... silicone rubber stopper OO into the hole on the receiver J to cover the dip switches NOTE The battery will weaken with age and should be replaced before leaking takes place as this will damage the hand unit Dispose of used battery properly and keep the battery out of the reach of children 4 Installing the receiver Position the house supply wires AAA to one side of the slide on mounting bracket A ...

Page 10: ...cting nut BB Connect the receiver J white wire to the household white wire neutral using a wire connecting nut BB Secure each wire connecting nut using electrical tape WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician Wiring the fan to the...

Page 11: ...in the mounting bracket A Push up the canopy C and turn clockwise until the alignment post KK engage to the round hole and the screws DD engage to the key slots Firmly tighten the two mounting screws DD Align the oval shape on the canopy C with canopy bottom cover FF Push up the canopy bottom cover FF until the screw DD heads engage to the slots on the canopy bottom cover FF so that the magnetic c...

Page 12: ...g the light fixture Installing the crystal shade 3 Remove the three screws PP from the light kit pan H Align the hook XX on the crystal shade I with the round hole at the outer rim of the light kit pan H and hang the crystal shade I to round hole in place Carefully push up the crystal shade I to the light kit pan H align the three screws holes on the crystal shade I with the three screws holes on ...

Page 13: ...n a lower setting without affecting your comfort A Warm weather B Cool weather 1 Power ON OFF Press and release the button to turn the fan and light on or off Press and hold the button for 5 seconds to use the walk away time delay this will active the light for 30 seconds the light will be activated at 50 brightness 2 Fan Speed LEDs on the fan speed button will illuminate to the corresponding spee...

Page 14: ... blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement Repeat for each blade Any measure ment deviation should be within 1 8 Run ...

Page 15: ...blems missing parts Before returning to the store call Home Depot Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 800 986 3460 HOMEDEPOT COM HOMEDECORATORS Retain this manual for future use ...

Reviews: