background image

14

Troubleshooting

Problem

Solution

The fan will not start.

 

Check the main and branch circuit fuses or breakers.

 

Check the line wire connections to the fan and switch wire connections in the switch housing.

 

Check the battery in the remote control.

 

Ensure you are in the normal range of 10-20 feet.

 

Remember to turn off the power supply before checking the dip switch settings.

The fan is noisy.

 

Ensure all motor housing screws are snug.

 

Ensure the screws that attach the fan blade bracket to the motor hub are tight.

 

Ensure the wire nut connections are not rattling against each other or the interior wall of the switch housing.

 

Allow a 24-hour “breaking in” period. Most noises associated with a new fan disappear during this time.

 

If you are using the Ceiling Fan light kit, ensure the screws securing the glassware are tight. Check that the light 
bulbs are also secure.

 

Ensure the canopy is a short distance from the ceiling. It should not touch the ceiling.

 

Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box.

The fan wobbles.

 

Check that all blade and blade arm screws are secure.

 

Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on 
the ceiling above the tip of one of the blades. Measure from a point on the center of the blade to the point on the 
ceiling. Rotate the fan until the next blade is positioned for measurement, and measure from the same point on 
each blade to the ceiling. Repeat for each blade. Any measurement deviation should be within 1/8 in. Run the fan 
for ten minutes. If the fan continues to wobble please contact Customer Service and a balancing kit will be sent 
to you at no charge.

 

Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade 
attachments twice a year. Make sure they are secure. It is not necessary to remove the fan from the ceiling.

 

Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning, as this could damage 
the motor, or the wood, or possibly cause an electrical shock. Use only a soft brush or lint-free cloth to avoid scratching the finish. 

 

You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty. Cover small scratches with a 
light application of shoe polish.

 

You do not need to oil your fan. The motor has permanently-lubricated sealed ball bearings.

WARNING:

 Make sure the power is off before cleaning 

your fan.

Care and Cleaning

Summary of Contents for 56-HARB

Page 1: ...ate the trust and confidence you have placed in Home Decorators Collection through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Home Decorators Collection Item xxxx xxx xxx Model 59299 UL Model 56 HARB USE AND CARE GUID...

Page 2: ...ets also referred to as flanges during assembly or after installation Do not insert objects in the path of the blades WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device WARNING Electrical diagrams are for reference only If you are using a light kit refer to the light kit instructions manual to make the electrical connections Optional ...

Page 3: ...er express warranty Home Decorators Collection hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a limitation on how long an implied...

Page 4: ...t Description Quantity AA Blade attachment screws 16 BB Blade bracket screws 16 CC Plastic wire connecting nuts 3 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size BB CC AA ...

Page 5: ...mbly 1 Part Description Quantity F Blade arm 5 G Blade 5 H Light kit pan 1 I Light kit fitter assembly 1 J Frosted white glass 1 K Receiver 1 L Remote control 1 M Extension lead wire 1 N Battery 1 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation continued PA...

Page 6: ...et box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs 15 9 kg Use only UL listed outlet boxes marked Acceptable for fan support of 35 lbs 15 9 kg or less Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy touches the downrod then remove the decorative canopy bottom cover and ...

Page 7: ... B by inserting it into the motor collar GG and turning it clockwise until it is tight Re tighten the setscrew FF on the collar GG on top of the fan motor assembly E NOTE This fan is equipped with a safety tab HH Should the setscrew FF ever become loose while the fan is running in reverse the safety tab HH will engage and stop the fan from falling CAUTION To ensure wobble free operation and to avo...

Page 8: ...let box as shown Securely tighten the two mounting screws JJ Carefully lift the fan motor assembly E up to the slide on mounting bracket A Insert the ball portion of the ball downrod assembly into the socket of the slide on mounting bracket A Turn the ball downrod B assembly clockwise until it is seated with the tab of the slide on mounting bracket A aligned with the slot in the ball 1 2 WARNING T...

Page 9: ... be replaced before leaking takes place as this will damage the hand unit Dispose of used battery properly and keep the battery out of the reach of children 4 Installing the receiver Position the house supply wires AAA to one side of the slide on mounting bracket A position the fan wires BBB to the opposite side Insert the narrow end of the receiver N as shown flat side towards the ceiling into th...

Page 10: ...cting nut CC Connect the receiver K white wire to the household white wire neutral using a wire connecting nut CC Secure each wire connecting nut using electrical tape WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician Wiring the fan to the...

Page 11: ...ttom of the canopy C properly Assembly Hanging the Fan continued 7 Installing the blades to the blade brackets 1 Attach a blade G to the blade arm F by aligning the holes on blade G and blade arms F and inserting the screws AA into the holes and through the blade G and blade arm F Tighten each screw to secure the blade G Repeat this step for each blade G and blade arm F Assembly Attaching the Fan ...

Page 12: ...y I to the wires from the fan motor assembly E by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch cup Push the light kit fitter assembly I up to the light kit pan so that the two loosened screw heads fit into the keyhole slots Turn the light kit fitter assembly I clockwise to secure Re install the screw that was removed in the first step Make sure ...

Page 13: ...ith a remote control to operate the speed and lights of your new ceiling fan Speed setting for warm or cool weather depends on factors such as the room size ceiling height number of fans and so on The fan is shipped from the factory with the reversing switch YY positioned to circulate air downward If airflow is desired in the opposite direction turn your fan off and wait for the blades to stop tur...

Page 14: ...hen blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of the blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement and measure from the same point on each blade to the ceiling Repeat for each blade Any measurement deviation should be within 1 8 in Run the ...

Page 15: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet o...

Reviews: