background image

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 13

Care and Cleaning ............................................................. 14

Troubleshooting ................................................................. 14

1. 

To reduce the risk of electric shock, ensure the electricity has 
been turned off at the circuit breaker or fuse box before you 
begin.

2. 

All wiring must be in accordance with the National Electrical 
Code ANSI/NFPA 70 and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

3. 

The outlet box and support structure must be securely mounted 
and capable of reliably supporting 35 lbs. (15.9 kg). Use only 
UL Listed outlet boxes marked”Acceptable for Fan Support of 
35 lbs. (15.9 kg) or less”.

4. 

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

5. 

Do not operate the reversing switch while the fan blades are 
in motion. You must turn the fan off and stop the blades before 
you reverse the blade direction.

6. 

Do not place objects in the path of the blades.

7. 

To avoid personal injury or damage to the fan and other items, 
use caution when working around or cleaning the fan.

8. 

Electrical diagrams are for reference only. Light kits that are 
not packed with the fan must be UL-listed and marked suitable 
for use with the model fan you are installing. Switches must be 
UL General Use Switches. Refer to the instructions packaged 
with the light kits and switches for proper assembly.

9. 

After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box. 
The wires should be spread apart with the grounded conductor 
and the equipment-grounding conductor on one side of the 
outlet box.

10. 

All setscrews must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury,

do not bend the blade brackets (also referred to as

flanges) during assembly or after installation. Do not

insert objects in the path of the blades.

WARNING:

 Suitable for use with solid-state speed 

controls.

WARNING:

 To avoid possible electrical shock,

turn the electricity off at the main fuse box before

wiring. If you feel you do not have enough electrical

wiring knowledge or experience, contact a licensed 

electrician.

WARNING:

 Electrical diagrams are for reference

only. Optional use of any light kit shall be UL-listed

and marked suitable for use with this fan.

WARNING:

 To reduce the risk of fire or electric

shock, “this fan should only be used with fan speed 

control part no. MR140A manufactured by Satellite 

Industrial Co., LTD” or control part no. AP-8RDL 

manufactured by Dawnsun.

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury,

use only the screws provided with the outlet box.

READ AND SAVE THESE INSTRUCTIONS.

CAUTION:

 Changes or modifications not expressly 

approved by the party responsible for compliance 

could void the user’s authority to operate the 

equipment.

CAUTION:

 Do NOT use this fan with a dimmer switch 

or wall control. Using a dimmer switch or wall control 

will damage the fan.

WARNING:

 To reduce the risk of electric shock, this 

fan must be installed with an isolating wall switch.

Summary of Contents for 56082

Page 1: ... quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Home Decorators Collection Item XXXX XXX XXX Model 56082 UL Model 52 VAGN WINDLOW 52 INCH CEILING FAN To view an instructional video on how to install this product 1 Go to www homedepot com and enter either the Item or Model number found ...

Page 2: ... spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 10 All setscrews must be checked and retightened where necessary before installation WARNING To reduce the risk of personal injury do not bend the blade brackets also referred to as f...

Page 3: ...nder the warranty invalid There is no other express warranty Home Decorators Collection hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not ...

Page 4: ... Part Description Quantity AA Blade attachment screws 21 BB Blade bracket screw 11 CC Plastic wire connector 3 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size AA CC BB ...

Page 5: ... arm 5 Part Description Quantity H Blade arm medallion 10 I Light kit pan 1 J Light kit fitter assembly 1 K Shatter resistant bowl 1 L Receiver 1 M Remote control battery included 1 N Extension lead wire 1 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation con...

Page 6: ...Use the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy C touches the ball downrod assembly B then remove the decorative canopy bottom cover and turn the canopy C 180 before attaching th...

Page 7: ...locks Loosen the two canopy screws DD located in the bottom of the mounting bracket A and turn the canopy counterclockwise to remove the mounting bracket A from canopy C Assembling the fan Loosen but do not remove the setscrew GG on the collar FF on top of the fan motor assembly E Install the downrod B by inserting it into the motor collar FF and turning it clockwise until it is tight Re tighten t...

Page 8: ... outlet box Securely tighten the two mounting screws JJ Carefully lift the fan motor assembly E up to the slide on mounting bracket A Seat the hanger ball portion of the ball downrod assembly B in the mounting bracket socket Ensure that the tab on the slide on mounting bracket A socket is properly seated in the groove in the hanger ball 1 2 WARNING To reduce the risk of fire electric shock or othe...

Page 9: ... silicone rubber stopper OO into the hole on the receiver L to cover the dip switches M L ZZ 1 2 3 4 ON D O 1 2 3 4 ON DIP 1 2 3 4 ON D O 1 2 3 4 ON OO NOTE The battery will weaken with age and should be replaced before leaking takes place as this will damage the hand unit Dispose of used battery properly and keep the battery out of the reach of children 4 Installing the receiver Position the hous...

Page 10: ...cting nut AA Connect the receiver L white wire to the household white wire neutral using a wire connecting nut AA Secure each wire connecting nut using electrical tape WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician Wiring the fan to the...

Page 11: ...e canopy C and turn clockwise until the alignment post KK engage to the round hole and the screws CC engage to the key slots Firmly tighten the two mounting screws DD Install the decorative bottom cover EE by aligning the cover slots with screws in the bottom of the canopy C Rotate the bottom cover EE clockwise to lock in place 7 WARNING When using the standard ball downrod mounting the tab in the...

Page 12: ...supply circuit to the fan before installing the light kit pan Installing the shatter resistant bowl 3 Place the shatter resistant bowl K into the light kit pan I aligning the three flat areas on the top flange of the shatter resistant bowl K with the three raised dimples in the light kit pan Turn the shatter resistant bowl K clockwise until it stops CAUTION Make sure the power is off before attach...

Page 13: ...t on a lower setting without affecting your comfort A Warm weather B Cool weather 1 Power ON OFF Press and release the button to turn the fan and light on or off Press and hold the button for 5 seconds to use the walk away time delay this will active the light for 30 seconds the light will be activated at 50 brightness 2 Fan Speed LEDs on the fan speed button will illuminate to the corresponding s...

Page 14: ... blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement Repeat for each blade Any measure ment deviation should be within 1 8 Run ...

Page 15: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet o...

Reviews: