system which makes servicing easier.  

 

Hard copper pipe generally comes in two types. Use the thicker "L" type 
copper pipe rather than thinner "M" type copper pipe.  

 

Follow all local plumbing and building codes.

 

Installation  

1. 

Turn off the main line water shutoff valve to the house. 

2.  Next, open all plumbing fixtures in the house in order to drain the lines of as much  
water as possible. 

3.  The filter should be installed on the main water supply line near where it enters the 
house, at any point past the main shut-off valve for the whole house, but before pipes 
branch off into multiple directions. However you may choose to locate the filter after the 
line branches to the inside and outside plumbing depending on your desire for filtered 
water in your outdoor plumbing. 

4. 

Measure, cut and remove a section of the main incoming water line near where the 

system is to be installed. When determining the length of pipe to cut, account for  filter 
width, shut off valves, union fittings, nipple fittings, pressure gauges (if used) and by-
pass valve (if used). Allow  this line to drain thoroughly. Smooth the newly cut ends 
down to avoid jagged points or edges. 

Your filter should be located in a dry, level 

area and protected from freezing, and direct sunlight.

  

5. 

Place a shutoff valve and/or a pressure gauge (optional) immediately on either side of 

the filter for future ease of service.  

6. 

Securely mount the whole house filter using supplied mounting bracket and bolts. 

Ensure system is level. 

7. 

You may now need to adjust pipe length or distance. Fit a pipe union onto the cut 

section of the main Water Line IN. (see diagram). 

8. 

Fit together pipe union and shut off valve. Use Teflon tape on threaded fittings. 

9. 

Simultaneously fit together shut off valve and whole house filter using pipe nipple or 

hex nipple to draw then together on the IN side of the filter. 

10.

  Fit pipe hanger on water IN side for additional support. 

11.

 Simultaneously fit together filter and the shut off valve on the OUT side of the filter. 

Fit pipe union to shut off valve on OUT side. 

Customer Service Hotline 1-877-693-PURE 

 

 

 

Page 5 

Home Master

® 

Water Filter  Owners Manual 

12.

 Check pipe length and pipe union length to see if additional pipe length or union 

required. Join pipe union and pipe. 

13.

 Fit pipe hanger on water OUT side for additional support. Connect ground jumper 

cable (if necessary) 

14.

 A) Remove each filter from its packaging, B) replace it in the sump taking care 

that it slots over the standpipe at the bottom of the sump,  

15.

 

IMPORTANT: 

YOU MUST APPLY 
GREASE TO THE 
ENTIRE SURFACE 
OF BOTH ORINGS 
AND HOUSING 
THREADS - TO 
ENSURE SMOOTH 
OPERATION, 
OPENING , 
CLOSING, AND A 
PROPER SEAL.  

FAILURE TO DO SO 
WILL LEAD TO 
INCOMPLETE 
CLOSURE & LEAKS, 
OR MAKE IT 
NEARLY 
IMPOSSIBLE TO 
OPEN THE UNIT 

SOME GREASE IS ADDED AT THE FACTORY. PLEASE ADD MORE. 

16.  NOTE FILTER ORDER: The SEDIMENT filter treats the water first. The CARBON filter 
treats the water last. In 3 housing units the IRON or Nanofiber filter will be in the 
center position. 

17.

 Fit sump with filter to housing cap hand-tighten, then fit snug with housing 

wrench.  Housing is closed when a 1/8” gap is observed between cap and lower lip. 

 

Turing the water back on

 

Turn your water on slowly. In a few minutes, the sound of water entering the system 
will stop. After the unit is installed, it is necessary to flush the unit thoroughly. Do this 

Summary of Contents for HMF1C

Page 1: ...anitize System At filter change At filter change At filter change At filter change At filter change It is a good idea to keep a set of spare orings 1 per housing You may need to change them each time you open the housing Note Filter life will vary based upon contaminant level and usage Note protect system against freezing direct sunlight and the elements This information subject to change without ...

Page 2: ...5 A Pour 2 cups of unscented concentrated bleach in each empty sump and close the system to hand tight and fit snug tight with the wrench DO NOT over tighten B Drain your hot water heater C Open the main water supply to the system D Open a faucet at the furthest point from the system and run water until you smell the chlorine Flush the toilet Repeat at each point of use moving towards the filter s...

Page 3: ...er Customer Service Hotline 1 877 693 PURE Page 3 Home Master Water Filter Owners Manual Installing The Whole House Filtration System Tools Required Safety glasses hacksaw Towels Soldering iron or torch Flat head screwdriver Power drill Medium Crescent wrench Teflon tape Monkey wrench Parts required not included 2 shut off valves bypass valve s optional 2 hex nipples or pipe nipples pressure gauge...

Page 4: ...ce Fit a pipe union onto the cut section of the main Water Line IN see diagram 8 Fit together pipe union and shut off valve Use Teflon tape on threaded fittings 9 Simultaneously fit together shut off valve and whole house filter using pipe nipple or hex nipple to draw then together on the IN side of the filter 10 Fit pipe hanger on water IN side for additional support 11 Simultaneously fit togethe...