40
troubleshooting
No gas at the burner, and the gas tank is empty
1. Gas valve was left open.
Check if system gas valve, drainage connector or stove’s gas valve
have been left open, allowing the gas to escape. ensure stove is
tur
ned off, gas valve is closed and drainage connector is screwed
shut.
2. System has not been fed for some time.
Feed the system.
3. Water level in the digester tank has fallen too low allowing gas
to escape through sink.
Fill the digester tank with water until you see liquid pouring out of
Fertilizer Outlet.
4. Cold weather caused bacteria to stop gas production.
Reduce feeding volumes (refer to cold weather operations on page
34) or wait for the weather to warm up.
5. There is a gas leak somewhere in the system or along the gas
tubes.
To locate leak, apply soapy water along the gas pipes, tank flanges
and pipe joints. Leakage will cause bubbles to appear. Fix the leak
or replace the leaky element.
6. pH level in the system is abnormally low (<5.0), causing gas
production to stop (see page 39 for details on pH checking).
Contact HomeBiogas for assistance.
The most likely cause is accumulation of water condensation in the
gas pipe, blocking the free flow of gas to the stove.
Ensure there are no bends/dips in the pipe from stove to system that
water can collect in. The gas pipe should also be installed at a slight
angle from the system to the stove.
Gas tank is filled but there is no gas flow, or
flame sputters and dies frequently
1. Drain collected water from the gas pipes.
i. Open the water drainage valve and drain any collected
condensation from the gas tube (refer p38).
ii. If problem persists, you may need to empty the 10mm gas tube
separately - open clamps, disconnect the 10mm gas tube from
the reducer fitting and stove and drain out any water from the
tube. Blowing through the tube or using an electric air pump to
pass air through the tube will help to clear out collected water.
iii. Close drainage connector and reopen gas valve.
Summary of Contents for HBG 2.0
Page 1: ...1 HB2 OM 050221 2021 HOMEBIOGAS VERSION 050221 HBG 2 0 HOUSEHOLD BIOGAS SYSTEM OWNER S MANUAL ...
Page 13: ...13 i ii iii x4 parts bag 1 i i ii iii LUBRICANT LUBRICANT ...
Page 15: ...15 1 parts bag LUBRICANT LUBRICANT ...
Page 16: ...16 x2 Inlet sink orientation short cord plunger slot towards back long cord towards front ...
Page 19: ...19 check filled digester for leaks contact HomeBiogas if any leaks are seen ...
Page 20: ...20 ii i LUBRICANT x2 ...
Page 21: ...21 i ii iii v iv 90 ...
Page 22: ...22 x40 i ii iii use dry sand only sand bags ...
Page 23: ...23 2 top x16 left right x16 back front x8 1 2 3 x2 x8 x8 x2 x2 x2 x2 x2 x2 x2 x2 x2 x2 x2 ...
Page 24: ...24 iii ii GAS FILTER i remove 2 protective stickers from cover base of gas filter ...
Page 29: ...29 ...
Page 37: ...37 ...
Page 43: ...43 ...
Page 47: ...47 ...