background image

signal can be affected by mobile phones, TV, electrical appliances or other
electronic interference.  To get the best performance of the Atomic clock,
please install the home receiver near a window and away from large metallic
objects.  If the unit is not working properly, change the unit position.  There
may be some interference at this location.  

TROUBLE SHOOTING

Indoor and Outdoor temperatures do not match when
placed next to each other 

-

Each sensor is manufactured to be +/- 2 degrees in accuracy under normal
conditions.  So it is possible to have up to four degrees difference shown on
the separate temperature sensors (one could be “+2 degree” and the other
“-2 degrees”.  Additionally, the calibration curve is different between the two
units because of the greater temperature range of the outdoor sensor.
Errors are usually noted on the extreme ends of the temperature ranges.

Base unit is not accepting remote transmissions 

-

The units may not be properly synchronized or the batteries may need to be
replaced.  See “GETTING STARTED” section beginning on page 2 of the
instructions for detailed instructions.  With the two units next to each other,
attempt synchronization.  Remember to always place the remote sensor
within the effective transmission range and away from large metal surfaces.

What is the recommended battery type?

Your unit will come with an AC adaptor.  As a backup power source, we 
recommend using only alkaline batteries for replacements.

Where can I mount the remote sensor?

To get accurate readings and to prolong the life of your sensor, we rec-
ommend that you mount it out of direct sunlight and rain.  Fog and mist will
not affect the sensor, but large volumes of soaking rain may.  To guard
against this, we recommend that you mount it under the eve of your house,
your garage or any other suitable place that will keep it out of direct sun 
and rain.

8

Outdoor Temperature Reading shows “- -”

This is usually an indication that the channel selector (located in the top left
corner of the home receiver) is set incorrectly to receive the signal from the
remote sensor.  If you have only one remote sensor, ensure that the channel
selector is set to “1”.  To change the channel, press the “channel” button
located on the front of the home receiver. 

The home receiver may also be “scrolling” - looking for sensor readings from
more than one remote sensor.  This home receiver can support up to three
remote sensors (only one is included). If it is looking for more than one
remote sensor, a “     ” icon will appear below the channel designator.
Again, to select a reading from just one remote sensor, press the “channel”
button to remove the scroll icon and ensure that the channel selected now
reads “1”.

The unit is “locked” - I can’t perform unit functions -

When this occurs, the unit maybe in “forced synchronization” mode. If the
radio antennae icon shows “waves” projecting from it, the unit is attempting
to synchronize with the atomic clock frequency. To override, simply press the
“ - ” button on the back of the unit. You will now be able to perform all other
functions.

SPECIFICATIONS

Range of temperature/humidity measurement:
Indoor temp :

+32 F to +122 F (0 C to + 50 C)

Indoor humidity:

20% to 99% RH

Remote sensor:

-4 F to +140 F (-20 C to +60 C)

Channel:

max. 3 remote sensors

Temp. Alert:

Indoor Temp/ Humidity and Ch 1 thru 3

Transmission:

max. 100 ft. (30 m) open area, RF434 MHz

Resolution:

0.1 degree for temperature, 1% for humidity

Clock: WWVB 

Radio-controlled 

Power source:

AC adaptor - home receiver
2 Alkaline AA batteries - remote sensor

9

DWS-170-IB SP\ENG  10/12/04  11:32 AM  Page 9

Summary of Contents for EnviraStation DWS-170

Page 1: ...ntre otras aquellas garantías implícitas de idoneidad y comerciabilidad están limitadas a la duración total de dos años a partir de la fecha de compra original Para obtener un servicio cubierto por la garantía para su producto HoMedics puede entregar la unidad personalmente o enviarla por correo junto con su recibo de compra fechado como prueba de la compra el franqueo pagado junto con un cheque o...

Page 2: ...ace the unit away from sources of interference such as mobile phones appliances TV etc 4 Antenna icon will appear on screen if the radio time reception is successful The radio controlled clock will have a daily synchronization at 1 00 am everyday If previous attempts of reception were unsuccessful the home receiver will attempt synchronization each hour until successful 5 Each reception cycle is m...

Page 3: ... of projection 1 To turn the projected information 180 degrees press the SETTING ALARM TIME 1 Hold the CLEAR button for 3 seconds 2 To select either first alarm A1 or second alarm A2 Press on back to toggle between selections Press CLEAR to confirm your selecton 3 Set alarm time Press on the back of the unit to enter the desired Hr Min values Press CLEAR to confirm 4 To view alarm time Press CLEAR...

Page 4: ...ver will learn the random code of the remote sensors and log it in as channel 1 then set the additional remote sensors as channel 2 and channel 3 if necessary The home receiver can monitor up to 3 separate sensors Once a channel is registered it will not accept any new sensors However registered channels can be erased by removing the batteries in the remote sensor or the home unit When replacing b...

Page 5: ...olumes of soaking rain may To guard against this we recommend that you mount it under the eve of your house your garage or any other suitable place that will keep it out of direct sun and rain 8 Outdoor Temperature Reading shows This is usually an indication that the channel selector located in the top left corner of the home receiver is set incorrectly to receive the signal from the remote sensor...

Page 6: ... step backward Fast backward Select PST MST Atomic time seek CST EST CLEAR Clear memory at Min Max Alarm time setting ALARM display Read alarm time 5 sec at normal mode MIN MAX Read minimum maximum record 5 sec ALERT Temp alert on off Enter temp alert setting CHANNEL Select Channel 1 2 3 Delete current channel auto scroll SNOOZE Backlight on 5 seconds BACKLIGHT Trigger snooze alarm stop alarm 10 1...

Page 7: ...d to those implied warranties of fitness and merchantability are limited in the total duration of two years from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated sales receipt as proof of purchase postpaid along with check or money order in the amount of 5 00 payable to HoMedics to cover handling Upon receipt we will...

Page 8: ...erencia tales como teléfonos celulares artefactos televisores etc 4 El icono de la antena aparecerá en la pantalla si la recepción de la señal horaria de radio es exitosa El reloj controlado por radio tendrá una sincronización diaria todos los días a la 01 00 am Si los intentos de recepción anteriores fracasaron el receptor doméstico intentará sincronizar cada hora hasta tener éxito 5 Cada ciclo d...

Page 9: ...ará lecturas de Temperatura en descenso si es más de un grado en una hora ALERTA DE TEMPERATURA HUMEDAD Oprima ALERT para encender o apagar la alerta de temperatura y humedad 1 Oprima y mantenga el botón ALERT al respaldo del receptor doméstico por 3 segundos para ingresar al modo de ajuste de alerta El icono de las condiciones al interior empieza a destellar 2 Oprima para seleccionar entre alerta...

Page 10: ...sensores diferentes Una vez que se registra un canal no aceptará ningún sensor nuevo Sin embargo los canales registrados pueden borrarse retirando las pilas del sensor exterior o de la unidad interior Cuando cambie las pilas del sensor exterior recuerde borrar el canal correspondiente del receptor interior retirando las pilas y desenchufando el adaptador o seleccione el canal respectivo del sensor...

Page 11: ...mperatura exterior indica Esto en general indica que el selector del canal ubicado en el rincón superior izquierdo del receptor doméstico no se encuentra ajustado correctamente para recibir la señal del sensor remoto Si usted tiene sólo un sensor remoto asegúrese de que el selector del canal esté ajustado en 1 Para cambiar el canal presione el botón channel canal ubicado en el frente del receptor ...

Page 12: ...T MST Búsqueda de señal CST EST Atómica CLEAR Borra el máx min Configuración de hora ALARM de la memoria que se muestra de alarma Lee el tiempo de alarma durante 5 segundos en el modo normal MIN MAX Lee los registros máximo y mínimo durante 5 segundos ALERT alerta Encendido y apagado Ingresa la configuración de de la alerta de temperatura la alerta de temperatura CHANNEL Selección de Canal 1 2 3 B...

Reviews: