Front Plate

PVC Tubing
Inserts Here

Back Plate

Suction Feet

Impeller

Pump Inlet

Flow
Control
Lever

Housing

MAINTENANCE: 

1

.  To keep water clean:

 

Periodically change water and clean the product according to the 

water condition. Keeping the water clean prevents the water from 

becoming sticky and forming micro-organisms. We recommend 

distilled water to prevent mineral build-up.

2.  To clean off hard water deposits on the base:

 

Use a mixture of vinegar and water to clean and remove any mineral 

build-up on the base and pump.

3.  Keeping the water at an optimum level:

 

Add water periodically to keep water level at an optimum level and to 

avoid shortening the life of the pump. 

NOTE: 

Never let the pump run 

dry.

4.  Fountain Storage

 

Unplug the fountain from the electrical outlet, empty the water, let 

the fountain dry completely, and store in a dry, cool place.

5  To clean the pump:

 

Unplug from electrical outlet. Remove it from the base of the 

fountain. Use a small brush or stream of water to remove any debris 

(Fig. 6)

 

Caution:

 

All servicing of this fountain must be performed by authorized 

HoMedics service personnel only.

TROUbLESHOOTING

•  If the pump fails to operate, check the following:

  Check the circuit breaker, or try a different outlet to make sure the pump 

is getting electrical power. 

NOTE:

 Always disconnect from electrical outlet 

before handling the pump.

  Check the pump discharge and tubing for kinks and obstructions. Algae 

build-up can be flushed out.

  Remove the pump inlet to access the impeller area. Turn the rotor to 

ensure it is not broken or jammed.

 

NOTE: 

Monthly maintenance will add to your pump’s life.

•  If the pump gurgles, spews, or “burps”:

  Check the water level to make sure the pump has enough water to function.

•  Obtaining a desired water level:

  Check the water level daily the first week to measure the rate of 

evaporation; refill with water as needed.

  NOTE:

 It is recommended the pump be set at its highest speed and later

  adjusted to a lower setting if desired. Be sure to unplug the pump before 

adjusting the speed setting.

Summary of Contents for WF-LILY

Page 1: ...funcionamiento en cualquier país que no sea aquél para el que fue diseñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA O...

Page 2: ... disabled persons Use this appliance only for its intended use as described in this manual Do not use attachments not recommended by HoMedics specifically any attachments not provided with the unit Never operate this appliance if it has a damaged cord plug pump cable or housing If it is not working properly if it has been dropped or damaged return it to Homedics Service Center for examination and ...

Page 3: ...at this time Fig 3 4 Fill the ceramic bowl with enough water to ensure the pump is fully submerged Fig 4 5 Plug the cord into 120V household outlet The switch located on the power cord con trols the fountain If pump doesn t operate rotate in line switch once to turn on and once more to turn off Monthly maintenance will add to your pump s life NOTE Ensure that the electrical cord loops below the el...

Page 4: ...it from the base of the fountain Use a small brush or stream of water to remove any debris Fig 6 Caution All servicing of this fountain must be performed by authorized HoMedics service personnel only Troubleshooting If the pump fails to operate check the following Check the circuit breaker or try a different outlet to make sure the pump is getting electrical power NOTE Always disconnect from elect...

Page 5: ...ty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES IN NO EVENT SHALL THIS WAR...

Page 6: ... el objetivo para el cual fue diseñado y como se describe en este manual No use accesorios no recomendados por HoMedics particularmente accesorios que no se proporcionan con la unidad Este artefacto no debe ponerse en funcionamiento si el cable el enchufe la bomba el hilo o el armazón están dañados Si no está funcionando adecuadamente si se ha caído o dañado envíelo al Centro de servicio de HoMedi...

Page 7: ...receptáculo de cerámica con una cantidad suficiente de agua de modo que la bomba quede completamente sumergida Fig 4 5 Enchufe el cable a un tomacorriente doméstico de 120 V El interruptor ubicado en el cable de energía controla la fuente Si la bomba no funciona gire el interruptor en línea una vez para encender on y una vez más para apagar off El mantenimiento mensual alargará la vida útil de la ...

Page 8: ...s de establecer la velocidad 14 15 MANTENIMIENTO 1 Para mantener el agua limpia Cambie el agua periódicamente y limpie el producto en función del estado del agua Mantener el agua limpia evita que la misma se vuelva pegajosa y que se formen microorganismos Recomendamos el uso de agua destilada para evitar la acumulación de minerales 2 Para limpiar los depósitos de agua dura de la base Use una mezcl...

Reviews: