22
23
11 Response to power recovery
When the operating voltage is switched on (recovery of mains
voltage), the actuator checks its components. The device LED
will flash if an error is detected during this check. This is repeated
continuously and the device does not perform its function. If the
test is completed without errors, the actuator transmits a wireless
telegram containing its status information. To prevent all actuators
from transmitting at the same time when power is recovered (after
a mains power failure or a disconnection, for example), there is a
random delay before the actuator transmits. During this time, the
device LED flashes (as in teach-in mode). If the delay is very short,
this flashing may be almost imperceptible.
12 Maintenance and cleaning
The product does not require any maintenance. Enlist the help of
an expert to carry out any repairs. In the event of an error, please
return the device to our service department.
13 Technical data
Instructions for disposal
Do not dispose of the device with regular domestic waste.
Electronic equipment must be disposed of at local collection
points for waste electronic equipment in compliance with the
Waste Electrical and Electronic Equipment Directive.
The CE Marking is simply an official symbol relating to the
free movement of a product; it does not warrant a product’s
characteristics.
Transmit / receive frequency:
868.30 MHz
Open air range:
Up to 100 m
Power supply:
230 V / 50 Hz
Standby consumption:
0.5 W
Volume (audible):
105 dB
Ambient temperature:
+5°C to +55°C
Degree of protection:
IP20
Housing:
PBT
Housing colour:
RAL 9010 pure white
with diffuse masking frame
Dimensions (H x W x D):
125 x 63 x 40 mm
(not incl. plug)
File formats supported:
MP3 (CBR, VBR, ABR)
Memory cards supported:
microSD/SDHC, max. 255
titles