40
Start-up
*
Specialist knowledge required for installation:
The following specialist knowledge is particularly important during in-
stallation:
•
The ‚5 safety rules‘ to be used: Disconnect from mains;
Safeguard from switching on again; Check that system is
deenergised; Earth and short circuit; Cover or cordon off
neighbouring live parts;
•
Select suitable tool, measuring equipment and, if necessary,
personal safety equipment;
•
Evaluation of measuring results;
•
Selection of electrical installation material for safeguarding
shut-off conditions;
•
IP protection types;
•
Installation of electrical installation material;
•
Type of supply network (TN system, IT system, TT system) and
the resulting connecting conditions (classical zero balancing,
protective earthing, required additional measures etc.).
There may be no open conductor ends in the
flush-mounting box!
5.2.3 Installation in multiple combinations
You can mount the wall-mount remote control with the at-
tachment frame
(A)
provided or use it with frames of other
manufacturers as well as integrate the remote control
(B)
into a multi-gang frame. You can flexibly fix the mounting
plate
(G)
to the wall using adhesive strips or screws. For
mounting with multiple combinations, make sure that the
mounting plate of the remote control is seamlessly aligned
to the already fixed mounting plate/retaining ring.