circuit is equipped with residual current device tripping sensitivity 30 mA.
These installations must be carried only by a specialist with electro
qualifications.
Residual current circuit protector will provide safe operation and protect the
operator in the event of damage to the insulation alternator. Residual current
circuit breaker disconnects the electrical circuit in the event of a discrepancy
between the electrical force-output alternator and parts of the circuit connected
to ground at the output of the circuit breaker.
Must not be combined PE and N !
3. OPERATING CONDITIONS
1.
COMPLIANCE WITH NATIONAL SAFETY STANDARDS.
The device is
manufactured in compliance with European safety standards. May not be
complied national standards.
2. Devices operate at maximum heeling 15 degrees to the horizontal.
3. The machine must be protected from humidity and rain, chemically
aggressive environments, mechanical damage, excessive overloading -
exceeding the tech. parameters rough treatment.
4. Each user must know its maximum rated power generator, which
must not be exceeded.
Generator is equipped with a thermal fuse,
which serves as a protection against prolonged overloads. If the power is
interrupted during the use, it can be caused by breaking the fuse due to
constant overloading. In this case, wait a short period of time, remove the
cause of overloading and then switch on the fuse again by pressing the
button located near the outlets. Thermal fuses have values
corresponding to the values of each type of generator. If the replacement
is necessary, use original spare parts.
Thermal fuse can not secure
single very strong overloading exceeding several times the rated
power generator. It can result in severe damage to the alternator, for
which the manufacturer does not bear any responsibility.
5. When connecting electrical machines and appliances to the generator it
is essential to observe the technical parameters of electric powered and
connected devices. If in doubt consult your dealer or the manufacturer of
power generators.
6. Coefficient determines the approximate multiple increase "label" the
power of powered devices, which may occur short-term during the
operation, especially during start-up equipment. Most equipment has a
coefficient of 1 except for the following (the list is not complete, it is
indicative only).
The connected powered device
Coefficient
Pressure washers
3
Fridge
3,5 -5