When the HSK-200Z starts, it will query the associated power meter to get the

currentsetup.   

 

Auto scene activator     

 

This function enable us to start the scenario when the power meter detect that the 
associated device is turned on. Usually, the power meter notify the HSK-200Z for its 

status only. However, it can be used to trigger the scenario as well. For example, if the 
projector power meter detects the projector is on, the HSK-200 will execute the whole 

scene 1 if the configuration xxx is non-zero.     

 
In this way, we can use the power button of the projector to start the presentation 
mode.In addition, the AV power meter can be used to trigger the normal mode and the 

AVR power meter can be used to start the meeting mode.     

 
This function is disabled by default. In order to start this function, please use the CONF 
key of HSK-100 to setup the configuration 7&8.     

 

4.5. Device calibration     

 

The HSD-400Z will send SCENE ID 1 to all devices listed in the group 1 when the current 

exceed the value specified in Configuration 1. In addition, it will send SCENE ID 2 to all 

evices listed in the group 2.     

d

 

However, these values may not be able to detect the current sonsumption of your 
devices.We may need to determine a good high threshold and a low threshold. We can 

use the HSK-100Z to adjust these configurations. This is inconvienent since we need to 
adjust thevalue and verify it. If it does not work, we need to retry again.     

 The device calibration is a special mode of the HSK-200Z. The procedure is     

 

 

 

Use HSK-100Z to add power meter into the HSK-200Z.     

 

 

Press and hold the program button of the HSK-200Z.     

 

 

The LED of HSK-200Z will start to blinking.     

 

 

Press the power button of the device attached to the power meter. 

 

 

Wait the device is completely on or off.     

 
• Repeat press the power button until the LED stop blinking. The calibrated 

values will be saved at configuration 1 & 2 of the power meter.     

 

4.6. Add IR keys     

 

The AV starter kit provides 20 IR keys which will be sent in pre-defined scenarios.   

 

4.7. Define key for power off     

For most projectors, we need to press power key twice in order to turn off the projector.     

 

Summary of Contents for HSK-200Z

Page 1: ...User s manual of HSK 200Z 1 Introduction The HSK 200Z often work with the HSD 400Z HSM 300Z and HSK 100Z as the above picture ...

Page 2: ...SK 100Z Universal IR remote controller with Z_Wave repeater One HSM 300Z projector screen cotnroller In addition it can work with other window shade device or switch dimmer as well In this document we assume that we use HSK 100Z as the primary controller The HSK 200Z can work with any Z Wave compatible primary controller which support ASSOCIATION and CONFIGURATION command classes Please refer to t...

Page 3: ...3 Supported command class ...

Page 4: ...and class is mapped to the scene activation command classes The value will be mapped into 3 ofit is the scene ID If the value is higher than 3 it The basic get will return the last invoked scene 3 2 Simple AV control The simple AV control can be used to send IR signals from the internal database Pleaserefer to the table in the appendix 3 3 Association The HSK 200 supports the following groups ...

Page 5: ...t the HSK 100Z into add node mode by using ADD DEVICE Press and release the program button in the bottom of the device by using a needle Thedevice will broadcast node information and enter learning mode The HSK 100Z will add the HSK 200Z from the network and show dolid OK LED If there is any error the Error LED will be turn on instead ...

Page 6: ......

Page 7: ...4 3 Install the IR cable Put the HSK 10 or HSK 15 to plug in the socket of HSK 200Z ...

Page 8: ...e HSK200Z support up to three power meter to control three AV devices They areassociated to the following IR codes Projector Power key xxx AV power key xxx AVR power key xxx We can use the ASSOC key of HSK 500Z to include a power meter Please use the following table to select the group to associate ...

Page 9: ...group 1 when the current exceed the value specified in Configuration 1 In addition it will send SCENE ID 2 to all evices listed in the group 2 d However these values may not be able to detect the current sonsumption of your devices We may need to determine a good high threshold and a low threshold We can use the HSK 100Z to adjust these configurations This is inconvienent since we need to adjust t...

Page 10: ...fferent scenes However light defined in the above procedure can be activated from the HSK 100Z only If you want to use other devices such as HSK 50 or any scene controller you need to add a HSC 50Z light scenario controller by using HSK 100Z so that the HSK 200Z can relay the scene activation commands to the HSC 50Z 5 WARRANTY This warranty does not cover or apply to Limited One 1 Year Warranty a ...

Page 11: ... in accordance with the installation May cause harmful interference to radio communication However there is no guarantee that interference Will not occur in a particular installation if this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more o...

Reviews: