ADVANCED CONFIGURATION
Parameter
Settings
14
Enable / Disable BASIC SET command
0-Disable, 1-Enable
0-Default
1 byte—Parameter size
15
Value of BASIC SET
0-Sends 255 value for open and 0 value for closed
1-Sends 0 value for open and 255 value for closed
0-Default
1 byte—Parameter size
32
Defines value of LOW BATTERY
10-50 (10%-50%)
20-Default
1 byte—Parameter size
LIMITED WARRANTY
HomeSeer Technologies, LLC will repair or replace, at its option, any part of the device, which proves to be defective in workmanship or
material under normal use, in the USA except in the states of Alaska or Hawaii, for a period of one year from the date the device is pur-
chased. During the warranty period, HomeSeer Technologies, LLC will repair and provide all parts necessary to correct such defects, free of
charge, provided the device has been operated in accordance with the manufacturer's guidelines. The Customer will return the device to
HomeSeer Technologies, LLC for testing and repair or replacement. Should you need service, during warranty period or beyond, contact
HomeSeer to obtain return authorization before shipping your device to HomeSeer Technologies, LLC.
SPECIFICATIONS
Operating Temp Range
0ºC to 40ºC
Power Supply
Requires (2) AAA 1.5V Batteries
Z-Wave Frequency | Range
Z-Wave Certification
908 MHz (US) | Up To 300 Ft line of sight
Z-Wave Plus
Dimensions
Sensor Body: 3 x 1.1 x .75 inches
Magnet Piece: 3 x .5 x .75 inches
Wake Up Settings
HS-DS100+ can be programmed to wake up and send its status on a specific regular interval.
Wake up interval:
Available settings: 0-2678400 (seconds)
Default setting: 0 - A setting of “0” disables the regular reporting feature and requires the sensor to be manually woken up to send updates.
Default setting when added to HomeSeer systems: 43200 (12 hours)