background image

Operation 

 

The table below describes 4 main operation modes available. 
Refer to Z-wave Configuration section for setting Parameters 1, 4~6. 
 

Control 
mode 

When sensor triggers 

Corresponding action 

Lux 
sensor 

PIR 
sensor 

Floodlight behavior 

Z-wave alert   
(if Par. 4 = 1) 

PIR 
control 
(default) 

 
Par.5=1 
Par.6=0 

Night 

Triggered 

ON at night, when PIR 
triggers, (Par. 1 sets the 
ON period) 
 
OFF during Day 

Sends alert 
whenever PIR 
triggers. 

Lux 
control 
only 

 
Par.5=1 
Par.6=1 
 

Night 

Not 
relevant 

ON at Night 
 
OFF during Day 

Sends alert 
whenever PIR 
triggers. 

Controller 
control 

 
Par.5=0 

Not 
relevant 

Not 
relevant 

ON/OFF controlled by 
controller directly 

Sends alert 
whenever PIR 
triggers. 

Walk Test 

 
Lux knob 
and Timer 
knob both 
set to "T 

Not 
relevant 

Triggered 

On for 5 seconds 

Sends alert 
whenever PIR 
triggers. 

 
 
 
 
 

Programming 

 

Z-Wave Group 

The unit supports either one of two Z-wave Association Groups: 

Group 1

: Association with 1 Controller node. 

Group  2

:  Association  with  4  nodes  (i.e.  end  devices  such  as  smart  plugs  and 

other  lighting  controllers).  This  allows  the  PIR  detector  on  the  unit  to  transfer 
commands  directly  to  other  Z-wave  end  devices  without  the  participation  of  the 
controller. This has the effect that when its detector triggers, all devices associated 
with unit will be operated. 

 

Z-Wave Plus Information 

Role Type 

Node Type 

Installer Icon 

User Icon 

Slave Always ON 
 

Z-Wave Plus 
node 

Sensor Notification 
Device Type (Home 
Security) 

Sensor Notification 
Device Type (Home 
Security) 

 
Association Command Class 

Group 

Max Node 

 

Version 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

ZDK6.82.xx), Z-wave SmartStart supported 

Firmware Version 

xVy (x=1,y=0 means 1V0) 

Hardware Version 

 

Manufacturer 

Manufacturer ID 

Product Type 

Product ID 

0x000C (HomeSeer) 

0x0201 

0x000C 

 

AGI (Association Group Information) Table 

Group 

Profile 

Command Class & Command (List) 
N bytes 

Group Name(UTF-8) 

General 

Device Reset Locally Notification 
Notification Report 
Binary Report 
Sensor Multilevel Report 
Basic Report 

Lifeline 

Control 

Basic Set 

PIR Control 

Summary of Contents for HS-FLS100-G2

Page 1: ...roller when motion is sensed and when the LUX level changes Likewise the smart hub or home controller can send Z Wave commands back to the HS FLS100 G2 to turn floodlights ON and OFF This added functi...

Page 2: ...KER BEFORE INSTALLATION Taking down the existing floodlight 1 With mains supply turned off if possible remove the lamps from the bulb holders of the existing floodlight to avoid any damage during the...

Page 3: ...st Mode Walk Test The user can perform a walk test to ensure the PIR detector s range falls within the desired area of coverage 1 Walk through its PIR Detector coverage area The floodlight turns on wh...

Page 4: ...t will automatically enter Inclusion mode when first powered up after a factory reset 1 Turn off power to the floodlight by turning off the wall switch 2 Try to relocate the Z wave controller nearer t...

Page 5: ...ode Group 2 Association with 4 nodes i e end devices such as smart plugs and other lighting controllers This allows the PIR detector on the unit to transfer commands directly to other Z wave end devic...

Page 6: ...will always send a notification report to the controller when triggered 3 Multilevel sensors auto report interval set the interval of periodic lux level report and temperature report to the controlle...

Page 7: ...gle and direction of the lamps Z wave controller cannot communicate with the unit Out of range 1 Relocate the controller closer to the unit 2 Install a Z wave repeater such as smart plugs or other AC...

Page 8: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase...