HS- | Z-Wave Plus Floodlight Sensor 

Be sure to visit our website for the most up-to-date information about this product: 
https://homeseer.com/support-home/ 
 

Overview 

The HS- is a PIR module that’s designed to retrofit onto existing outdoor 
floodlights.  It features a PIR sensor  to detect motion through movement  of heat 
sources  and a LUX  sensor for determining brightness of its surroundings.  It  is 
equipped with Z-Wave Plus wireless communication capability that will convert an 
ordinary motion-activated floodlight into a smart home device. 
 

Conventional Floodlight Mode 

HS- can be used as a conventional motion-activated floodlight sensor to 
power floodlights when motion is sensed during dark hours. Controls are provided 
for manual adjustment of LUX sensitivity and floodlight ON times. 
 

Smart Floodlight Mode 

When added to a smart home system, HS- will send Z-Wave commands 
to the smart hub or home controller when motion is sensed and when the LUX 
level changes. Likewise, the smart hub or home controller can  send Z-Wave 
commands back to the HS- to turn floodlights ON and OFF. This added 
functionality provides a very high level of flexibility not typically available in 
conventional motion-activated floodlights. 
 

Smart Sensor Mode 

HS-  can be installed and used simply as an outdoor motion and LUX 
sensor. Floodlight functionality is not required. This provides some interesting 
security and smart home possibilities! 
 

S2 Security 

This product supports the S2 security protocol that uses encrypted Z-Wave Plus 
messages to communicate to other security-enabled  Z-Wave Plus  products. A 
security-enabled Z-Wave Plus controller must be used in order to fully utilize the 
security features of this product.   
 
 
 

 

Product Overview 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 PIR Lens 

 Lux knob 

 LED indicator (hidden behind lens) 

 Timer Knob 

 Link button 

 Threaded arm 

 

Below diagram show a typical assembly of HS- on a floodlight fixture (not 
provided). 
 
 
 
 
 
 
 
 
 
 
 
 
 

(Wall mount)   

 

 

 

(Under Eave mounting) 

 
 
Note: Please read this entire instruction manual before you start the installation. 
 

 

 

 

 

 

 

Summary of Contents for HS-FLS100+

Page 1: ...e controller when motion is sensed and when the LUX level changes Likewise the smart hub or home controller can send Z Wave commands back to the HS FLS100 to turn floodlights ON and OFF This added functionality provides a very high level of flexibility not typically available in conventional motion activated floodlights Smart Sensor Mode HS FLS100 can be installed and used simply as an outdoor mot...

Page 2: ...tart early during the day WARNING TURN OFF POWER BY REMOVING POWER FUSE OR TURNING OFF CIRCUIT BREAKER BEFORE INSTALLATION Taking down the existing floodlight 1 With mains supply turned off if possible remove the lamps from the bulb holders of the existing floodlight to avoid any damage during the installation 2 Carefully detach the floodlight from the wall by removing its mounting screws Keep all...

Page 3: ...n turn off It is now in Test Mode Walk Test The user can perform a walk test to ensure the PIR detector s range falls within the desired area of coverage 1 Walk through its PIR Detector coverage area The floodlight turns on when you move and turns off after approximately 5 seconds Wait for the floodlight to turn off before the next test 2 When you are satisfied with the coverage area you can now s...

Page 4: ... QR code label on the back of the unit on the insert card inside the packaging 6 Turn on the floodlight using the Z Wave controller to check if the auto inclusion is working properly If Auto Inclusion fails refer to the Troubleshooting section regarding Manual Inclusion Note HS FLS100 supports the latest S2 security o ffered by Z Wave certified controllers If your controller supports S2 please refe...

Page 5: ...ler Icon User Icon Slave Always ON Z Wave Plus node Sensor Notification Device Type Home Security Sensor Notification Device Type Home Security Association Command Class Group Max Node 1 1 2 4 Version Protocol Library 3 Slave_Enhance_232_Library Protocol Version 5 3 6 71 03 Firmware Version xVy x 1 y 1 means 1V1 Hardware Version 1 Manufacturer Manufacturer ID Product Type Product ID 0x0060 Everspr...

Page 6: ...ux level measured Tolerance of 30 lux Level above 250 will be read back as 250 Sensor Type Precision Scale Size Sensor Value 0x03 0 1 2 250 Command Classes The module supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COM...

Page 7: ...ion is complete 2 Press the Link button 3 times within 1 5 seconds to put the unit into inclusion mode Exclusion 1 Put the Z Wave Controller into exclusion mode 2 Press the Link button 3 times within 1 5 seconds to put the unit into exclusion mode Factory Reset This procedure should only be used when the controller is inoperable 1 Press the Link button 3 times within 1 5 seconds to put the unit in...

Page 8: ...the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or ope...

Reviews: