background image

 

HS-LS100+ Z-Wave Leak Sensor 

OVERVIEW 

HS-LS100+ is a compact, easy to install leak sensor. It is designed to control other Z-Wave devices directly 

or it may be used with a variety of Z-Wave certified home controllers to launch automation events or scenes. 

 

Applications 

 

• 

Use to activate Z-Wave devices such as sirens or water valve controllers when a leak is sensed.   

• 

Use to trigger home automation events (aka “scenes”, “automations” or “robots”) when a leak is sensed.   

 

Configuration   

HS-LS100+ is battery powered and includes a Z-Wave network button, LED indicator and a magnetic wall 
mount/wired probe assembly. The unit may be deployed as a free-standing sensor (using built-in probes) or as a 
wired remote sensor (via the wall mount/wired probe assembly).   
 

Z-Wave Network Installation 

Remove the back cover by rotating counter-clockwise and install 1 ER14250 battery 

(included) inside HS-LS100+. Include the sensor into your Z-Wave network using the instructions below. Then, 
replace the back cover. Use the instructions below to 

include 

or 

exclude 

HS-LS100+ to/from your Z-Wave network.   

Inclusion 

(recommended if your home controller supports “S0” or “S2” Z-Wave encryption)   

1. Put your home controller into Z-Wave ‘inclusion’ mode.   

2. Quickly triple-press the Z-Wave network button, then release it. Wait for the inclusion process to finish.   

 

Exclusion 

 

1. Put your home automation controller into Z-Wave ‘exclusion’ mode.   
2. Quickly triple-press the Z-Wave network button. Wait for the exclusion process to finish.   

   

Reset 

(Use this procedure to reset HS-LS100+ to factory settings when the Z-Wave controller is missing or 

inoperable).   
1. Press and hold the Z-Wave button for 20 seconds. Release the button once the LED stops blinking and glows 
solidly.   
 

Physical Installation 

 

Free-standing installation: 

Simply place the leak sensor on a flat horizontal surface in the area where a leak might 

occur.   

Remote installation: 

Install the included magnetic wall mount/wired probe assembly in the location of your choice 

(using the supplied mounting hardware) and attach the HS-LS100+ to it by aligning the 3 probes with the 3 holes in 
the mounting bracket. Position and install the wired probe in the area where a leak might occur or where you wish 
to detect liquid.   

Leak Sensor Operation 

 

HS-LS100+ is designed to transmit a Z-Wave command when liquid is sensed. It will also transmit another command 
when liquid is no longer sensed.   

Shock Sensor Operation 

 

The shock sensor is designed to transmit a Z-Wave command when HS-LS100+ has been physically moved. This 
sensor is especially helpful in determining whether the unit has been removed from its mount or tampered with. 

 

Battery Sensor Operation 

 

The battery sensor is designed to report battery level with a Z-Wave command every 43200 seconds (12 hours). If 

Reviews: