HomingGame Crane Machine Manual
第
14
页
文控
:
无
Troubleshooting Fang Fasan
Fault phenomenon
Treatment method
The top of the crane is not
moving up and down
Can cause the rope to reverse the situation: only the limit switch failure or touch
the afternoon limit switch card failure
How to determine the limit switch card failure: through the above limit switch fault
handling, eliminate switch failure, through the observation of grasping the
downward motion in the end, but not immediately catch the upward movement,
but to see continue to let go of the rope down, release the rope to tighten the rope
to reverse. As the switch card failure. The way: you can make some lubricants
maintenance crane can be solved.
Crane grasp the start of the son
to tighten
Drive motherboard failure, replace the driver board
Error of catch limit switch under
crane tip
1 May day after the coin, have been caught empty (only MINI chance of grasping,
namely after the coin, no joystick crane claw down directly in the material mouth is
empty catch phenomenon of the fault normal without treatment, the normal
operation of a crane can be removed, or 10S fault display automatically cut).
2 crane can not go down in the end, that will also be back to report this error. If this
occurs, please enter the advanced system settings will be able to adjust the time to
claw down.
3 crown of the foot in the end, but the fault is the fault of the lower limit switch or
wire connection failure or motherboard failure.
Claws can drop normal, but the
rise is not normal or up to stop
for a while and then a paw and
loose state
1 please check whether the anti sway balancer is pressed. When the anti swing
balancer failure occurs, this does not rise, and the sound will appear corresponding
do not shake tips.
Fault of crane motor
If the crane self-test process cannot be run in accordance with established
procedures. Exclusion limit switch fault free, observe the driver board LED light is
normal, can judge the fault of motor crane. Crane or mechanical failure stuck
problem. Check out the replacement of crane motor stuck mechanical problems.
Press the key to grasp the object
can not carry out action
Change the grab button, or check the key connection is off
Claws can not be folded when
grasping
1 into the background to determine whether the grip force is set to 0 or too small
2 check if the coil is damaged. Observe whether the coil is blackened and burnt
3 check the claw connection wire is connected properly
4 for Mini 24V power supply is normal, handle the replacement power supply
The gift is easy to be taken away
or the gift is not ideal
Into the back office management system: grasp the force set interface to adjust the
grasp force to achieve the ideal effect of the gift slip