2) Insert a appropriate feeler gauge between the ignition
pulse generator and projection part of the rotor.
3) Push the ignition pulse generator firmly against the rotor
and tighten the ignition pulse generator bracket mounting
bolt. Remove the feeler gauge.
11-4
IGNITION PULSE GENERATOR INSTALLATION
1) Install the ignition pulse generator and loosely install the
ignition pulse generator bracket mounting bolts (6 x 25 mm
flange bolt).
• Take care not to pinch the generator wire harness with the
ignition pulse generator bracket.
b. INSPECTION
Measure the resistance between the terminal and the ignition
pulse generator base.
Resistance
297 – 363
Ω
0.5 ± 0.2 mm (0.020 ± 0.008 in)
[2]
PROJECTION POINT
Air gap (at rotor)
0.5 ± 0.2 mm (0.02 ± 0.01 in)
6 x 25 (2)
[2]
GENERATOR
WIRE HARNESS
[1]
IGNITION PULSE
GENERATOR BRACKET
[1]
FEELER
GAUGE