2-11
FAILURE BY ERROR CODE
*: No error code displayed. Can be displayed in Error Log Mode (P. 2-9).
Error code
Overload
Oil alert
Cause of failure
Fail-safe
Refer to
indicator indicator
page
batt
OFF
OFF
Battery under charged
When turning the ignition switch
2-13
to the START position, the starter
motor is stopped.
OIL
OFF
ON
Insufficient oil
Engine is stopped.
2-14
E-00
FLASH
OFF
Starter motor failure
When turning the ignition switch
2-15
to the START position, the starter
motor is stopped.
E-01
FLASH
OFF
Starter motor switch input failure
Display only
2-17
E-02
FLASH
OFF
Abnormal battery voltage
Engine is stopped.
2-18
E-03
FLASH
OFF
Engine temperature sensor
Display only
2-19
failure
E-04
FLASH
OFF
Governor function failure
Engine is stopped.
2-20
E-05
FLASH
OFF
GCU internal failure or inverter
Engine is stopped.
2-21
E-06
FLASH
OFF
unit internal failure
E-07
FLASH
OFF
GCU internal failure or inverter
Engine is stopped.
2-22
E-08
FLASH
OFF
unit internal failure
E-09
FLASH
OFF
E-10 or E-20
FLASH
OFF
Inverter and generator control
Engine is stopped.
2-22
unit communication error
E-11 or E-21
FLASH
OFF
Inverter internal communication
Engine is stopped.
2-23
error
*(E-12 or E-22)
ON
OFF
Inverter protection activated
After shutting down the AC output,
2-24
*(E-13 or E-23)
ON
OFF
the engine is left running at idle
*(E-14 or E-24)
ON
OFF
Inverter overheating protection
speed (2,300 rpm).
2-25
*(E-15 or E-25)
ON
OFF
activated
E-16 or E-26
FLASH
OFF
Inverter unit internal failure
Engine is stopped.
2-25
E-17 or E-27
FLASH
OFF
GCU internal failure or inverter
Engine is stopped.
2-26
E-18 or E-28
FLASH
OFF
unit internal failure
E-19 or E29
FLASH
OFF
E-1A or E-2A
FLASH
OFF
E-1b or E2b
FLASH
OFF
E-1C or E-2C
FLASH
OFF
Inverter unit internal failure
Engine is stopped.
2-25
E-1d or E-2d
FLASH
OFF
cap.02 EU65is 6500is (Eu).qxd 07.12.17 4:25 PM ページ2-11