5) Install the connectors to the brush holder and
AVR unit onto the bracket (2).
Connect the AVR unit connector.
AVR unit mount bolt (M5-16L) (2)
Brush holder mount bolt (M5-16L) (1)
Tightening torque: 3.0
N•m
Push the brush holders so that the brushes
will be perpendicular to the slip rings, and
tighten the brush holder mount bolt.
If the brush is installed oblique to the slip ring, there is possibility that the
brush holder can break when the screw is tightened: or the brush may break
when generator of started.
Make this process carefully.
6) Set stator cover with the crow inserted into slit
and bent (2 pcs).
Insert the bend into the slit and caulking
with commercially available pliers.
Brush holder
Brush holder
Connect
AVR
Bracket (2)
Bolt
Bolt
35