4-6.
CHECKING STATOR
1) Remove control panel and disconnect stator wires at the connectors.
2) Measure the resistance between terminals
on stator leads.
Check here the table (Fig 5-1)
If stator is faulty, replace it with a new one.
3) Check the insulation resistance between
stator core and each stator lead using a
megger tester.
If insulation is bad, replace stator with a
new one.
CIRCUIT TESTER
(Resistance)
MEGGER TESTER
46