4-8. CHECKING BRUSH
Check for continuity between the each brush tip
and wire terminal as shown.
CONTINUITY
:
(+)probe
①
②
③
④
(-)probe
①
-
-
-
○
②
-
-
○
-
③
-
○
-
-
④
○
-
-
-
The brushes must be smooth where they
contact the slip rings. If not, polish smooth the
brushes with sandpaper.
A brush that is not smooth produces arcs
between the brush and slip ring leading to
possible damage. Usable brush lengths are
from 7 mm to 11 mm.
A brush shorter than 7 mm must be replaced
because decreased contact pressure between
the brush and slip ring lowers generator
efficiency and output voltage.
7 mm
BRUSH
①
②
③
④