AVR
4-9. CHECKING
A.V.R.
(AUTOMATIC VOLTAGE REGULATOR)
1) Features
This A.V.R. operates to control the field
current in order to maintain the output
voltage for the AC current, which generated
by the magnetic flux by the field coil.
2) A.V.R. trouble may be identified by simply
looking at the A.V.R., or by the inter-lead
resistance with a tester, or actually
mounting it in the generator and operating
it.
Replace the case where the resistance is
significantly deviated from the measured new
one.
(
Ω
)(R
±
20%)
CIRCUIT TESTER
TESTER POLARITY
‘
-
’
(
Ω
)
White(a)
Red(b)
Green
①
White
②
Blue
③
Blue
④
TESTER
POLARITY
‘
+
’
(
Ω
)
White(a)
-
2.1M
5.0M
5.1M
4.2M
4.2M
Red(b)
1.8M
-
2.2M
2.2M
1.9M
1.9M
Green
①
4.6M
2.2M
-
4.9M
4.7M
4.7M
White
②
4.6M
2.2M
5.1M
-
4.6M
4.6M
Blue
③
4.0M
1.7M
4.5M
4.5M
-
4.0M
Blue
④
4.2M
1.7M
4.7M
4.7M
4.2M
-