4-13
dummyhead
dummyhead
TROUBLESHOOTING
POWER UNIT
DTC
Detecting Item
Failure Condition/
Possible Cause
Verification Item (Check in numerical order)
Applicable Part
Check for
(abnormal symptom)
3A102
CAN received
message
Short circuit between DLC
terminals
1. DLC (4P)
Short circuit
Open circuit in CAN
communication line
2. CAN wires between PDU
and battery pack (CAN L/
CAN H)
Open circuit
3A103
Rotor sensor
malfunction
Loosely connected
connector
1. Motor 8P connector
Loose or poor connection
Loosely connected
connector terminal
2. Motor 8P connector
terminal
Loose or poor contact
Open circuit in sensor wire
3. Rotor sensor wires
between motor and PDU
Open circuit
Damaged PDU
4. PDU
Replace PDU
Damaged motor
5. Motor
Replace motor
3A104
Output pulse
abnormality
Loosely connected
connector
1. Motor 8P connector
Loose or poor connection
Loosely connected
connector terminal
2. Motor 8P connector
terminal
Loose or poor contact
Open circuit in sensor wire
3. Rotor sensor wires
between motor and PDU
Open circuit
Damaged PDU
4. PDU
Replace PDU
Damaged motor
5. Motor
Replace motor
3A105
START/STOP
switch
malfunction
Loosely connected
connector
1. START/STOP switch
connector
Loose or poor connection
Loosely connected
connector terminals
2. START/STOP switch
connector terminal
Loose or poor contact
Open circuit in switch wire
3. Switch wires between
switch and PDU
Open circuit
Damaged PDU
4. PDU
Replace PDU
3A106
Regenerative
resistance
circuit
malfunction
Damaged PDU
1. PDU
Replace PDU
3A107
Pre-charge
circuit
malfunction
Damaged PDU
1. PDU
Replace PDU
3A110
FET thermistor
shorted/opened
Damaged PDU
1. PDU
Replace PDU
3A111
Motor
thermistor
opened
Loosely connected
connector
1. Motor 8P connector
Loose or poor connection
Loosely connected
connector terminal
2. Motor 8P connector
terminal
Loose or poor contact
Open circuit in sensor wire
3. Rotor sensor wires
between motor and PDU
Open circuit
Damaged PDU
4. PDU
Replace PDU
Damaged motor
5. Motor
Replace motor
3A112
Electrostatic
malfunction*
Abnormal charge of static
electricity
1. Running on insulator
• Operating location
• Ground line setting
between product and
ground
2. Static electrification on
frame while running
Damaged PDU
3. PDU
Replace PDU
* The strong electrostatic charging may be stopped the motor. If this DTC is indicated, review the installation condition of the
motor and/or the operating condition of the product.
Summary of Contents for GXE2.0S
Page 8: ...MEMO dummyhead dummyhead ...
Page 14: ...MEMO dummyhead dummyhead ...
Page 24: ...MEMO dummyhead dummyhead ...
Page 25: ...4 1 4 dummytext 4 TROUBLESHOOTING TROUBLESHOOTING INFORMATION 4 2 DTC TROUBLESHOOTING 4 6 ...
Page 40: ...MEMO dummyhead dummyhead ...
Page 44: ...MEMO dummyhead dummyhead ...
Page 50: ...MEMO dummyhead dummyhead ...
Page 57: ...8 1 8 dummytext 8 WIRING DIAGRAMS WIRING DIAGRAM 8 2 ...