18-17
c. INSTALLATION
1) Secure the alternator fuse cable and the starter cable with
the cable bracket A as shown.
2) Tighten the 8 x 18 mm flange bolt to the specified torque
while pushing the negative (–) starter cable against the
projection on the crankcase.
TORQUE: 26 N.m (2.7 kgf.m, 20 lbf.ft)
3) Install the harness band clip, that clamps the starter cable,
on the cable bracket B.
4) Clamp the alternator fuse cable and the starter cable with
the wire harness clamp.
Check that the cables are not interfering with the shift arm.
NOTICE
[1]
CABLE BRACKET A
[2]
STARTER CABLE
[2]
STARTER
CABLE (–)
8 x 18
[3]
WIRE HARNESS CLIP
[4]
HARNESS
BAND CLIP
[1] CABLE BRACKET B
[1]
CABLE BRACKET A
[2]
STARTER CABLE
[3]
ALTERNATOR
FUSE CABLE
[5]
PROJECTION
[6]
STARTER CABLE
(–) TERMINAL