17-13
11) Remove the 20 mm hex. nut from the neutral switch, then
remove the neutral switch from the neutral switch bracket.
12) Remove the 6 x 12 mm flange bolt from the detent arm,
then remove the 6 mm washer, detent arm and the detent
spring.
Check the detent arm bushing on the detent arm. Replace
the detent arm bushing if necessary.
13) Remove the detent arm bushing from the detent arm.
Replace the bushing with a new one on assembly.
Check the detent arm for deformation or damage, and
replace if necessary.
b. INSPECTION
• NEUTRAL SWITCH
Connect the tester between the terminals and push the switch
knob. There must be continuity when the switch knob is
pushed, and no continuity when the knob is released.
[2]
NEUTRAL SWITCH
BRACKET
[1]
20 mm HEX. NUT
[3]
NEUTRAL
SWITCH
[1]
NEUTRAL SWITCH
[3]
DETENT ARM
BUSHING
[4]
DETENT
SPRING
[1]
6 mm WASHER
6 x 12
[2]
DETENT
ARM