Mounting and Wiring 

 

Installation Notes 

 

  The communicator must be installed in accordance with the National Electrical Code, 

ANSI/NFPA 70. 

  The communicator must be mounted indoors within the protected premises. 

  Do not install in air-handling spaces. 

  Do not mount the communicator on or near metal objects, as this may affect radio 

communication. It is also good practice to avoid locating the communicator near 
wiring such as AC, telephone, HVAC, computer data cables, etc. 

  Unshielded, 22 AWG cable is recommended for the communicator power/data wires. 

  Do not connect to a receptacle controlled by a switch. 

Determining the Signal Strength to Select a Location  

When choosing a suitable mounting location, understand that signal strength is very important for 
proper operation.  For most installations using the internal antenna, mounting the unit as high as 
practical, and avoiding large metal components provides adequate signal strength for proper 
operation.  
You will use the communicator to determine signal strength in order to find a suitable mounting 
location.  

LTEM-P Initial Power Up

: Upon initial power up, the communicator LEDs blink in repeated 

sequence from top to bottom indicating network initialization. 

Green (REG) 

 Yellow (STATUS) 

 Red (FAULT) 

 Green (CELL) 

 Green (WIFI) 

This sequence may take up to 15 minutes. 

Do not reset power during this time.

  

When initialization is complete, the LEDs may blink (per their respective functions). 
After initial network setup, subsequent resets or power ups can take up to 90 seconds. 

 

1.

 

Unpack the communicator and open the case by pushing in the two bottom tabs with a 
screwdriver while separating the case front. 

2.

 

Temporarily connect the power adapter and the battery to the communicator. When initial power 
up is complete, you can remove the power adapter and use the communicator on battery power to 
find a suitable mounting location. 

3.

 

Choose the installation site with the best signal quality by observing the Cell LED; it should be lit 
solid. The best signal strength is usually found at the highest point in the building, near a window.   

Mark the location for the communicator.  

 

 

 

Summary of Contents for LTEM-PA

Page 1: ...LTEM PV LTEM PA Internet and Cellular Communicator Installation and Setup Guide R800 26394A 10 20 Rev A ...

Page 2: ......

Page 3: ...gth to Select a Location 7 Mounting the Communicator 8 Mounting the Module on a Wall 8 Mounting the Module on a VISTA Control Panel Cabinet 9 Wiring the Communicator 10 Wiring for VISTA Series ECP Control Panels 10 Wiring for Bus Connection Control Panels 11 Wiring the Fault Trigger Output 13 Internet Connection Ethernet or Wi Fi 13 Power Connections 14 Connecting the Power Adapter 14 Backup Batte...

Page 4: ...LTEM P Installation and Setup Guide ii Appendices 27 Appendix A Summary of LED Operation 27 Appendix B 28 Appendix C Glossary 29 Regulatory Notes 30 Summary of Connections Diagram Inside Back Cover ...

Page 5: ...ue to Resideo s continuing effort to improve our products your device may look slightly different than pictured General Information The LTEM P communicates via the Internet when service is available and switches to cell service when the Internet is not available provided the Communication Path is set to IP Cell Connection to the Internet is made by direct Ethernet cable to the router or via Wi Fi ...

Page 6: ... PROWIFIZW module only one method can be used Ethernet or Wi Fi not both Reports fire burg and status messages via the Internet Reports messages via cell as backup to Internet reporting provided that the Communication Path includes cell Allows uploading and downloading of VISTA control panel data Remote Services allow the end user to access their security system from their computer via a website A...

Page 7: ...ll not be reported Fault Trigger Output A fault trigger output trigger output terminal T1 activates upon the following communicator fault conditions if alarm reporting is enabled for the condition tamper power loss low battery battery charger fault and loss of network connectivity communication path loss The fault trigger output can serve as a fail safe trigger if programmed to do so to ensure the...

Page 8: ...se with compatible control panels that do not support ECP communication The communicator connects to the control panel via RX TX GND terminal block connections Reports are sent in Contact ID format Optional Accessories The communicator supports various plug in modules as follows LTE Communication Module PROLTE V PROLTE A If enhanced cell radio features are desired install the optional PROLTE Commu...

Page 9: ...cted Battery Life 5 Years approx NOTE The sealed lead acid battery used for backup will have reduced life expectancy when exposed to elevated temperatures The useful life of the battery at 25ºC 77ºF is approximately 4 years At 35ºC 95ºF this will drop to 2 years and at 45ºC 113ºF 1 year Battery life expectancy should be taken into account when locating the radio Fault Trigger Output Open collector...

Page 10: ...ech honeywellhome com Compass Version Compatible with Compass Version v2 2 35 1 or higher for VISTA series control panel IP Cellular Downloading Compliance This device has been tested by ETL to meet the following standards UL1610 Central Station Burglar Alarm Units UL1023 Household Burglar Alarm System Units UL365 Police Station Connected Burglar Alarm Units and Systems ...

Page 11: ...You will use the communicator to determine signal strength in order to find a suitable mounting location LTEM P Initial Power Up Upon initial power up the communicator LEDs blink in repeated sequence from top to bottom indicating network initialization Green REG Yellow STATUS Red FAULT Green CELL Green WIFI This sequence may take up to 15 minutes Do not reset power during this time When initializa...

Page 12: ...gh the opening in the case back or route through the removable knockouts located on the back cover NOTE Cable tie anchor points are located on the case back around the large center knockout below the terminal block for securing the wiring and providing strain relief 2 Secure the case back to the mounting surface using six screws 3 along the top 3 along the bottom After mounting install the Wall Ta...

Page 13: ...d bushing 6 Refer to the control panel s installation guide and complete the ECP wiring 7 Secure the wiring with cable ties as necessary NOTE Cable tie anchor points are located on the case back around the large center knockout below the terminal block for securing the wiring and providing strain relief 8 After all wiring is complete and the unit is powered up and the battery is connected attach t...

Page 14: ...ed with this connector See ECP Option 1 diagram below Alternatively connect the VISTA control panel s ECP keypad terminals directly to the communicator s RX TX and GND terminals as shown in the ECP Option 2 diagram below 2 Connect the power adapter wires to the communicator s PWR and GND terminals as shown Observe polarity 3 Secure the wiring with cable ties as necessary Cable tie anchor points ar...

Page 15: ...e following steps show typical connections However if using compatible DSC or Interlogix control panels refer to their respective sections below Typical Control Panel Bus Connections 1 Connect the communicator s RX TX and GND terminals to the appropriate terminals at the control panel See diagram below 2 Connect the power adapter wires to the communicator s PWR and GND terminals as shown Observe p...

Page 16: ... no alarms or faults in order to perform the scan The communicator is powered by the provided 9VDC Power Adapter only Do not connect power from the control panel to the communicator Connections for DSC PowerSeries Control Panels Interlogix Control Panel Connections This section applies to the following Interlogix NetworX NX Series control panels NX 8E NX 4V2 NX 6V2 NX 8V2 1 Connect the control pan...

Page 17: ...n connect to the Internet via Ethernet cable direct to a router or via Wi Fi using the optional PROWIFIZW Wi Fi Z Wave module The communicator can use only one Internet connection method Ethernet or Wi Fi not both Ethernet Cable Connection If using an Ethernet cable connection connect one end of the Ethernet cable Category 5 or higher to the communicator s RJ45 connector and the other end to the c...

Page 18: ...m power is lost power loss messages are reported within 1 3 hours of actual loss The communicator transmits a low battery message programmable when the battery reaches 3 8V 5 indicating subsequent messages may not be transmitted The system shuts down when the battery falls below 3 3V and radio transmissions are no longer possible If system power is restored before the communicator shuts down a pow...

Page 19: ...ete perform a Communications Test NOTES for PROLTE MODULE INSTALLATION Initial communicator power up sequence can take up to 15 minutes for network setup After initial network setup subsequent resets or power ups can take up to 90 seconds Installing the PROLTE module auto disconnects the built in LTE CAT M1 cellular device No additional programming of the PROLTE module is necessary no need to use ...

Page 20: ... Play You will also need the following information Communicator s MAC ID and CRC both found on a label on the communicator MAC ID CRC SSID and password for the router to which the communicator will be connected SSID Password With the Wi Fi module installed and the communicator powered up and battery connected do the following 1 Connect your smart device to the same Wi Fi network the communicator w...

Page 21: ...ions Do not connect the outside phone line to either the Dialer Capture module or the control panel There should be no connection to the outside phone line when using the Dialer Capture module For replacement installations make sure to disconnect the outside phone line when using the Dialer Capture module with the communicator Dialer Capture Control Panel Programming Notes After the Dialer Capture...

Page 22: ...o drop the phone line voltage and will not provide a dial tone to the control panel During this time the control panel will make retry attempts 8 for residential and more for commercial to dial out and send a report Until the control panel has completed the series of retry attempts it will not be able to detect a Telco fault To minimize the wait time for control panels that allow setting the Telco...

Page 23: ...side the case install the short adapter cable s SMA connector in the antenna port knockout and secure with the nut provided See diagram detail A 3 Route the adapter cable as shown then snap the adapter cable s MHF connector onto the communicator s main board external antenna connector See diagram below 4 Install the external antenna according to its instructions using the brackets and hardware pro...

Page 24: ...LTEM P Installation and Setup Guide 20 ...

Page 25: ...ubscriber ID four digit number obtained from your monitoring station Communicator s MAC ID and MAC CRC number located on the box and inside the communicator When programming is complete the communicator must be registered See the Registration section After any programming changes are made to bus connected control panels the communicator must be reset rebooted press and hold the Test switch for 10 ...

Page 26: ...alidated Select the desired time period IP Fault Time 00 99 Applicable only if comm path includes Ethernet or Wi Fi In the event there is a loss of contact with the network over the Ethernet or Wi Fi connection enter the time delay in minutes before the communicator notifies the central station IP failure will always be sent to the central station as Primary Communication Path Failure Use DHCP Sel...

Page 27: ...e central station within 1 3 hours after its detection A restore report is sent within 1 3 hours after power is restored Low Battery Report Select Unselect If selected sends a low battery report when a low battery condition exists A low battery restore is automatically sent when the low battery condition clears REMOTE SERVICES Remote Access Select Unselect Select to allow the end user to access th...

Page 28: ...rimary Comm Path Restore message is generated and the value of IP Connectivity programming parameter is changed from Auto Detect to Detected From this point on the software expects connectivity The auto detect logic will resume only when the parameter is changed back to Auto Detect Ethernet or Wi Fi depending on option selected in Comm Path choice ECP Status Codes When the communicator is configur...

Page 29: ...ogress When the registration successfully completes the communicator enters a normal operating mode the REG green LED turns off If registration is not validated by AlarmNet within 90 seconds the communicator times out and the REG green LED will be lit solid To register the communicator go to www alarmnet360 com Please have the following information available Primary City ID two digit number Primar...

Page 30: ...LTEM P Installation and Setup Guide 26 ...

Page 31: ...s FAULT red ON No contact with the network OFF Normal FAST BLINK No network contact AND loss of communication with the panel SLOW BLINK Loss of communication with the panel ECP fault CELL green ON Minimum required signal quality is present OFF Cell not enabled FAST BLINK Signal quality is poor WI FI ETHERNET green Wi Fi Connection if used ON Communicator connected to Internet via Wi Fi OFF Wi Fi n...

Page 32: ...5 9 Specific to RESIDENTIAL COMMERCIAL Control Panels Such as the VISTA 10P 15P and 20P series Communicator Trouble low battery ECP bus network Possible Compromise Indication E353 C08xx R353 C08xx Radio Fault E353 0 1xx R353 0 1xx Specific to COMMERCIAL Control Panels Such as the VISTA 128 250 series Communicator Trouble low battery ECP bus network Possible Compromise Indication E333 C08xx R333 C0...

Page 33: ...tworks and translates information from one network to the other The Gateway IP address is the IP address for the gateway IMEI International Mobile Equipment Identity number IP Internet Protocol IP Address A unique number consisting of four parts separated by periods for example 204 17 29 11 An IP Address can be fixed or static or dynamic where the IP Address is assigned via DHCP at every startup I...

Page 34: ... partie 15 des règles de la FCC et exempt de licence RSS d ISED Son fonctionnement est soumis aux conditions suivantes 1 Cet appareil ne doit pas causer d interférences nuisibles 2 Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable Responsible Party Issuer of Supplier s Declaration of Conformity Ademco Inc a subsidiary of Resideo Techn...

Page 35: ...een OFF Cell not enabled FAST BLINK Signal quality is poor WIFI ETHERNET ON Connected to Internet via Wi Fi or Ethernet green OFF Wi Fi Ethernet option not enabled FAST BLINK Option enabled no connection to Internet TOP 3 BLINK in UNISON Firmware OTA download in progress TOP 4 BLINK in UNISON Cell firmware OTA update in progress ALL 5 BLINK in UNISON SIM card not present or puk locked BLINK in SEQ...

Page 36: ...oprietary protocols de compiling firmware or any similar actions is strictly prohibited For Support visit www resideo com For Warranty information visit www security honeywellhome com warranty www resideo com Resideo Technologies Inc 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 2020 Resideo Technologies Inc All rights reserved The Honeywell Home trademark is used under license...

Reviews: