background image

 

ENROLL AND SET UP  

You must enroll the device in the control.  Refer to the 

control's programming instruction for detailed procedures. 
Set the controller in Programming Mode and when 

prompted: 

1.  Pull the battery tab to activate the PROSiXSHOCK. (Use 

the magnet if the battery tab is removed.) 

2.  The LED flashes (up to about 20 seconds*) during 

enrollment. 

  All services (Reed, Terminal Block, and Shock) are 

enrolled in sequential (or next available) zone numbers. 

  The device sends its unique MAC ID (Serial Number); 

the controller registers the device and displays the 

transmitter data on screen. 

*NOTE

: Enrollment time varies depending on the signal 

strength between the device and the controller. 

3.  When done, the LED is ON for 3 seconds to confirm 

enrollment.  

NOTE

: If the device is not successfully enrolled during 

the enrollment period, the LED turns off and the device 

powers down. Activate a tamper, wired service (loop) or 

the reed switch to restart the enrollment process. 

4.  Program each zone being used: 

Reed Switch Zone 

(loop 1) 

Terminal Block Zone

 (loop 2) 

Shock Zone

 (loop 3) 

After enrolling, verify adequate signal strength by 

conducting a sensor test (see controller’s instructions) with 

the device in its intended mounting location. Adjust the 

device location and orientation as necessary. 

 

 

IMPORTANT

: Once enrolled in a system, the 

PROSiXSHOCK cannot be used with another controller 

until it is removed from the current controller. See the 

Controller’s instructions for details. 

DEMO MODE (NO ENROLLMENT NEEDED) 

 

1.  Remove the battery pull tab from the device. 

2.  Install the mounting plate onto the back cover to insure both tampers are closed. 

3.  The device will attempt to pair with a control (Flashing green LED for ~20 seconds, which is visible through the top 

cover) 

4.  The Green LED will turn off and within a minute the device is defaulted to maximum shock sensitivity for 10 

minutes. 

5.  Strike the device in the palm of your hand, the red LED will flash through the front cover indicating a shock event. 

6.  When ready to learn the device into a control open/close the cover again or trip the reed switch using a magnet. 

The pairing time window will start again. 