![background image](http://html.mh-extra.com/html/honeywell/00001059-amdt-b/00001059-amdt-b_component-maintenance-manual-with-illustrated-parts-list_150604069.webp)
COMPONENT MAINTENANCE MANUAL
00001059
CLEANING
TASK 21-22-91-100-801-A01
1.
External Cleaning of a Unit
A.
Reason for the Job
WARNING:
– DO NOT BREATHE THE FUMES. THE SOLVENTS ARE DANGEROUS.
– USE EYE PROTECTION. DO NOT LET THE SOLVENTS TOUCH YOUR SKIN.
– CLEAN THE PARTS IN A ROOM WHERE AIRFLOW IS SUFFICIENT.
– DO NOT CLEAN NEAR AN OPEN FLAME.
CAUTION:
– CAREFULLY OBEY THE CLEANING PROCEDURES, OR REPLACE THEM WITH
A PROCEDURE WHICH IS SPECIFIED BY THE MANUFACTURER IF YOU USE
EQUIVALENT PRODUCTS.
– AFTER YOU COMPLETE THE PROCEDURE, YOU MUST PUT PROTECTIVE
CAPS OR APPLICABLE PACKAGING MATERIAL ON THE PARTS.
Self-explanatory
B.
Job Set-up Information
(1)
Consumable Materials
CODE
REFERENCE
DESIGNATION
M09A
LOCAL PURCHASE
DENATURED METHANOL
NOTE:
Refer to the Consumable Materials Table (Ref. TASK 21-22-91-941-801-A01) for
all the data in the list.
C.
Job Set-up
SUBTASK 21-22-91-620-001-A01
(1)
Preparation of the Unit
(a)
Put all the protective caps on the units.
D.
Procedure
SUBTASK 21-22-91-160-001-A01
(1)
External Cleaning of the Unit
WARNING: DO NOT USE DIPPING OR SPRAYING PROCEDURES FOR FULL UNITS.
DIPPING OR SPRAYING PROCEDURES ARE ONLY FOR ISOLATED PARTS.
(a)
Clean the unit with a lint-free cloth made moist with cleaning material (M09A). As an
alternative, use a soft brush.
(b)
Dry with low-pressure compressed air, or with a lint-free cloth.
E.
Close-up
Not applicable
21-22-91
Page 4001
Dec 15/06
The document reference is online, please check the correspondence between the online documentation and the printed version.