23
Mounting and Connection Instructions Blocking Element 3
8.
Technical data
Rated operating voltage U_b
12 V DC
Operating voltage range
9 V to 15 V DC
Current consumption in idle at U_b=12V DC
6.0 mA
Mean current consumption (max. 0.6 sec.)
Current capacity of outputs (high active)
50 mA max.
Bolt locking time
(Depending on operating voltage)
Approx. 0.8 to 1.2 sec.
Signal duration of actuation signal
30 ms
Installation position
Random
Locking bolt:
Material
Steel
Diameter
8.0 mm
Path
0
mm
Bolt counter force
2 kN
Shearing force (at side)
kN
Cable connection:
Length
4 m
Diameter
5.6
Position
at back, bottom or top
Magnetic contact:
VdS approval no.
as per class B)
Switching voltage
30 V DC
Switching current
100 mA
Release range
10 mm to 20 mm
Max. lateral offset
10 mm
Environmental class as per VdS
III
Operating temperature range
-25 °C to +55 °C
Storage temperature range
-40 °C to +85 °C
The stipulated value for the shearing force of 3 kN refers to a distance between the
face plate and the
of max. 4 mm (see Chapter 3).
Approx. 0.2 A
2 ±1.0
3
± 0.2 mm
G104503 (
Dimensions W x H x D
18 x 140 x 32 mm (without face plate)
Face plate, non-magnetic
Standard dimension: 20 x 2 x 190 mm
threaded sleeve
³
1)
1)
Type of protection DIN 40050 / EN 60529
Blocking element
IP 65 in installed condition
Magnetic contact
IP 67