48
Installation instructions / ACS-2 plus
Example:
Example:
1. 9-bit AC/CU Prot.
2.=>DIN prot.
3. RDT prot.
4. Event prot.
Status: Addr: 32; GAddr: 30; 19200 Baud
Change? Y/N:
_
The current value is marked with "=>". To modify the values enter "y" and confirm
with
Enter
. Then you can select one of the consecutive numbers.
Settings and their use:
9-bit AC/CU prot.:
------
DIN prot.:
Direct connection to RS232 (e.g., PC/notebook) or interface
converter
RDT prot.:
For modem operation
Event prot.:
For network operation via Ethernet interface
The following information can be checked and modified if necessary depending on
the selected protocol:
Baud rate:
The current value is marked with "=>".
The value can be changed by entering “y” +
Enter
(at the question
Change? Y/N)
and the consecutive number of the desired baud rate
(the factory setting is 19200).
Address:
The current address and the permitted address range are displayed.
The value can be changed by entering “y” +
Enter
(at the question
Change? Y/N)
and the desired address (the factory setting is 32).
Group address: The current group address and the permitted address range are
displayed. The value can be changed by entering “y” +
Enter
(at the
question
Change? Y/N)
and the desired address (the factory setting
is 30).
Difference between address - group address:
A maximum of 32 controllers can be managed via the address (addresses
1 - 32). An additional group address is used to extend the address range and
the number of controllers managed (max. 30 x 32 = 960 (
MultiAccess for
Windows
can currently manage a maximum of 512 controllers)).
Group address
Addresses
1
1 - 32
2
1 - 32
3
1 - 32
4
1 - 32
etc.
30
1 - 32
With the
event protocol
, the following fields must be checked or modified, if
Summary of Contents for 026547
Page 2: ... ...
Page 42: ...42 Installation instructions ACS 2 plus Connection component mounting diagram ...
Page 58: ...58 Installation instructions ACS 2 plus 14 2 ACS 2 plus structure ...
Page 88: ...88 Installation instructions ACS 2 plus ...
Page 89: ...Installation instructions ACS 2 plus 89 ...
Page 93: ...Installation instructions ACS 2 plus 93 ...