9.
Technical data
EU BUS-2/BUS-1
no. 032211.17
Item
Rated operating voltage U_b
12 V DC
Operating voltage range
9 V to 15 V DC
Current consumption at U_b=12V DC:
Evaluation unit
12 mA
£
Per sensor
3 mA
£
Per LED
1.3 mA
£
Transmission and control functions
Disarmed
via BUS
Clear function
via BUS
Alarm
via BUS
Tamper
via BUS
Sensor connections
IDENTLOC
4 connectible transmission units
Conventional
1 diff. detector group
with clear function
Display functions
visible from outside
1 totalling LED
in the housing
1 teaching mode LED
1 LED per sensor
with diagnosis function
Frequency range
125 kHz
Transmission power
no transmission power
Protection class as per DIN 60529
IP 40
Environmental class as per VdS
II
Operating temperature range
-5 °C to +45 °C
Storage temperature range
-25 °C to +70 °C
Dimensions (WxHxD)
118 x 118 x 31 mm
Color
Traffic white
(similar to RAL 9016)
Hereby, the Novar GmbH declares that the radio equipment IDENTLOC evaluation unit Item no. 032211.17 is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage https://www.security.honeywell.de/ in the service/
download area.
Mounting and Connection Instructions IDENTLOC Evaluation Unit
31