INSTALLATION INSTRUCTIONS
69-2305-03
VR9205R Series 1000
Direct Ignition Gas Control with
Integrated Gas/Air Module
APPLICATION
The VR9205R Direct Ignition Gas Controls with Integrated
Gas/Air Module have been developed for application in
domestic appliances with premix or atmospheric burners
and automatic ignition requiring a redundant gas valve.
They have been optimized for direct ignition applications.
The gas/air module is designed to amplify and modulate
the outlet gas pressure by means of a pneumatic link
between the gas and air flow by using the air pressure
difference. The valve may be used on either Natural gas
or LP gas applications.
• Valve capacities are shown in Table 1.
• For suffix letter designation, see Table 2.
a
Capacity based on 1000 Btu/ft
3
, 0.64 sp gr natural gas at 1 in. wc pressure drop (37.3 MJ/m
3
, 0.64 sp gr natural gas
at 0.25 kPa pressure drop).
b
Minimum and Maximum regulation is at the max fire. Minimum regulation at low fire is 9 KBtu/h at 0.7 in. WC outlet
pressure.
SPECIFICATIONS
Body Pattern:
Straight through; see Table 1 for inlet and
outlet size.
Electrical Ratings:
Voltage and Frequency: 24 Vac, 50/60 Hz.
Current Draw: 0.4A.
Capacity:
Regulation Range:
Natural-LP Gas Conversion Kits:
Valve is not
convertible.
Approvals:
CSA Design Certificate. File # LR 112491
Table 1. Valve Capacity.
a
Model
Size Inlet-
Outlet (in.)
AGA Certified
Capacity
AGA Certified Minimum
Regulation
AGA Certified Maximum
Regulation
KBtu/h
KBtu/h
KBtu/h
VR9205R
1/2 x 1/2
140
20
b
200
Table 2. Model Number Suffix Letter Designation.
Model Number
Suffix Letter
Ambient Temperature Range
Pressure Regulator Type
R
32°F to 158°F
(0°C to 70°C)
Standard opening with integrated gas/air module