Troubleshooting
Consult the Programming Functions section of this manual for more
detailed information on transmitter blinking sequences and
programming.
Consult the 301C controller user manual for more detailed information
on using the controller’s wireless network menu.
Problem Possible
Cause Solution
The transmitter
is not
connected to
301C controller
The transmitter has not
been powered up
Press pushbutton 1, then
pushbutton 2. If the transmitter is
on, LED 2 will blink once. If no
LEDs blink the unit is off and you
must power up the transmitter:
Press and hold pushbuttons 1 and
2. Count 5 blinks of both LEDs
and release.
Enable the 301C’s Association
mode (wireless Network menu)
Communication
problems:
The network can take up
to 2 hours to establish all
connections. Times are
affected by network
structure: Less
transmitters close to
301C, more time to
establish link); Distance
between furthest
transmitter and 301C
(more hops); Size of
network (the more
transmitters, the longer it
takes)
Make sur the unit is powered up
(see above)
Check that devices closer to 301C
are connected (is the unit closest
to it connected)
Activate a scan of all channels
(see Function 4 -Scan All
Channels ) and wait 30 minutes
Activate the 301C’s Association
mode and wait 50 minutes.
Reset network parameters (see
Function 5 -Reset Network
Parameters to Zero) and wait 50
minutes
If the transmitter has still not
connected, contact Technical
Support.
Summary of Contents for 301W
Page 2: ......
Page 3: ...Wireless Gas Monitoring Device 301W Installation and User Manual ERP 511398 5 07 ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 22: ......
Page 34: ......
Page 38: ......
Page 44: ......
Page 45: ...Dispositif de détection de gaz sans fils 301W Manuel de l utilisateur ERP 511398 5 07 ...
Page 46: ......
Page 48: ......
Page 50: ......
Page 52: ......
Page 64: ......
Page 72: ......
Page 86: ......