CEILING FAN & LIGHT REMOTE CONTROL
Item #0374118
Model #40011
User Guide
1. Read and keep this instruction sheet for future reference.
2. Switch off the power at the circuit breaker before working on receiver or ceiling fan.
3. If you are unfamiliar with installing electrical wiring contact a qualified electrician.
4. This unit is to be used for the control of a ceiling fan and its electrical source
must be AC 110/120V, 60Hz.
5. Do not install in damp location or immerse in water. For indoor use only.
6. Do not use this remote with fans that have pre-installed remote controls.
CAUTION:
To reduce the risk of fire or injury, do not use this product in
conjunction with any variable (rheostat) wall control.
This remote can work with a variety of hugger fan types, however, there
is typically very little space in the hanger bracket area to install a receiver.
Therefore, we do not recommend using this remote with hugger type or 5 speed
ceiling fans.
1. Turn power off at circuit breaker.
2. Remove ceiling fan canopy from the mounting bracket. Disconnect existing
wiring between ceiling fan and supply at electrical junction box.
3. Slide the receiver into the mounting bracket per FIG.1 being careful not to
pinch the antenna wire.
4. The receiver will be inserted between the downrod and the mounting bracket.
5. Make wiring connections per FIG. 2.
CAUTION:
Incorrect wire connection can damage this receiver and could
cause injury or fire.
6. Push all connected wires back into the junction box and reinstall the canopy
onto the mounting bracket.
7. Switch power back on at the circuit breaker.
8. Manually set fan speed to High and set light to On using the pull chains.
This remote is preprogrammed from the factory and should work right out of
the box once the battery is installed. Should, for any reason, reprogramming be
needed, please follow the learning process as follows:
1. After installation is complete, switch the power on. Within 30 seconds, remove
the battery cover on transmitter and insert 12V battery (included).
2. Use a small screwdriver or ballpoint pen to press and hold the “LEARN”
button, located in the battery compartment (see FIG. 3), for 3 seconds.
Fan will turn on at high speed and light (if installed) blinks 3 times. This
confirms that the
SMART SYNC
is active.
If user cannot finish the activation within 30 seconds, the main power must be
turned off and back on. This will reset the unit. Repeat steps 1 and 2 of the
ACTIVATING THE LEARNING PROCESS.
It is not necessary to redo the LEARNING process after replacing the battery.
NOTE:
To control two receivers with one transmitter, turn power on to both receivers
simultaneously and follow the learning process.
Slide the D/O switch, located in the battery compartment (See FIG. 3), to match
the bulb type in your fan. “D” is for incandescent bulbs and “O” indicates compact
fluorescent bulbs (CFL). Use a small screwdriver or ballpoint pen to slide firmly
left or right.
CAUTION:
Incorrect bulb setting can damage the receiver.
INSERTING RECEIVER
INTO CANOPY ASSEMBLY
CANOPY
MOUNTING
BRACKET
FIG 1
LIGHT
(BLUE)
MOTOR
(BLACK)
MOTOR
(WHITE)
WIRING THE RECEIVER
TO THE FAN
ANTENNA
AC IN (NEUTRAL)
AC IN (LIVE)
FIG 2
D/O (DIMMER
SWITCH)
LEARN BUTTON
REAR VIEW OF TRANSMITTER
(shown with battery cover removed)
FIG 3
IMPORTANT SAFETY INSTRUCTIONS
ACTIVATING THE LEARNING PROCESS (
SMART SYNC
)
DIMMER ON/OFF SETTING (D/O SWITCH)
RECEIVER INSTALLATION INSTRUCTIONS