Precision Platform 4022 Scanner
System Overview
10/4/07
p/n:
6510020208
1-2
1.2. Data sheet
Category Specification
Environmental
Conditions at End
Supports
•
Max. temp: 55ºC (130ºF) without Optional Air Purge
•
Max. temp: 94ºC (200ºF) with Optional Air Purge
Environmental
Conditions for Sensor
Enclosure
•
PPAK 4 - Max. temp: 100ºC (212ºF)*
•
Up to 95% RH (non-condensing)
* Temp is measured 150mm (6”) from the sheet and 600mm (24”) in from the
edge of the sheet
Head Air
Requirements
•
Dry instrument air [per ISO
8573-1 222
]
•
2 x 142 – 145 L/min @ 4.8 – 6.9 BAR (5 – 15 cfm @ 70 - 100 PSI)*
*Exact usage determined by sensor compliment
Low Pressure Purge
Air Requirements
(Optional)
•
Filtered
air
•
Inlet max temp. 48ºC (120ºF)
•
11.3
m
3
/min @ 25mm H
2
0 (400 scfm @ 1” H
2
0)
•
Duct connection: Cable end, 203 mm (8”) diameter
Required for scanners in high dust or greater than 55ºC (130ºF) environments
Head Coolant
Requirements:
•
Quality: Potable Water or ethylene glycol/potable water solution
•
Min. Pressure: 2.7 BAR (40 PSI)
•
Max Pressure: 4.1 BAR (60 PSI)
•
Max. Temp: 30ºC (86ºF)
•
Max. 7.6 L/min (2 gal/min)*
* Exact flow varies with conditions
Beams
•
Wide Flange Structural I-Beam W10x45
Maximum Beam
Length
•
Standard: Up to 8.5 m (336”) (
longer length available upon request
)
End Supports
•
13 mm (1/2”) gusseted steel plate
Scanner Mounting
•
Bottom mounting is standard.
Beam Covers
•
2.3 mm (0.09”) aluminum interlocking sections
Optional Beam Cover
Seals
•
Optional Dirty Environment Beam Cover Seal Kit available with
Neoprene beam cover seals
Surface Protection
•
Pretreatment per SSPC-SP 6
•
Pretreatment
primer
•
Rust-inhibiting urethane primer
•
Polyurethane finish coat
Weight
•
680 kg + 181 kg/m (1500 lb + 10 lb/in)
Carriage Track
•
Rectangular-cross-section pultruded track, 191mm (7.5”) W x 19mm
(0.75”) D, 74% fiberglass, 26% resin
Traversing System
•
25mm (1.0”) wide, fiber reinforced neoprene head drive belts
•
Belts are horizontally oriented
•
208 – 240 V AC motor, 0.37 KW (0.5 hp)
Passline
•
838 mm (33”) from top of mounting pad
Summary of Contents for 4022
Page 1: ...Precision Platform 4022 Scanner System Manual 6510020208 ...
Page 2: ......
Page 3: ...Precision Platform 4022 Scanner October 2007 ...
Page 22: ......
Page 72: ......
Page 94: ......
Page 126: ......
Page 162: ......
Page 170: ......
Page 234: ......
Page 239: ...Glossary p n 6510020208 10 18 07 11 5 VIO Virtual Input Output ...