2 - 1
2
Serial Default Commands
The following serial default commands are used to program the imaging features for your document reader. For complete
descriptions of each command, refer to the corresponding page in this manual. For non-imaging programming commands, refer
to the Bar Code Manual.
The following commands can be sent via a PC COM port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameter
A label representing the actual value you should send as part of a command.
[
option
]
An optional part of a command.
{Data}
Alternatives in a command.
bold
Names of menus, menu commands, buttons, dialog boxes, and windows that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity only):
Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage
Prefix
Three ASCII characters:
SYN M CR
(ASCII 22,77,13).
Tag
A 3 character case-insensitive field that identifies the desired menu command group. For example, all RS-232
configuration settings are identified with a Tag of
232
.
SubTag A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the
SubTag for the RS-232 baud rate is
BAD
.
Data
The new value for a menu setting, identified by the Tag and SubTag.
Storage A single character that specifies the storage table to which the command is applied. An exclamation point (
!
) performs
the command’s operation on the device’s volatile menu configuration table. A period (
.
) performs the command’s
operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent
changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^
What is the default value for the setting(s).
?
What is the device’s current value for the setting(s).
*
What is the range of possible values for the setting(s). (The device’s response uses a dash (
-
) to indicate a
continuous range of values. A pipe (
|
) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the
entire
set of commands available for the particular
storage table indicated by the Storage field of the command. In this case, the SubTag and Data fields should not be used
because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the
Tag field. In this case, the Data field should not be used because it is ignored by the device.
Summary of Contents for 4850DR
Page 1: ...4850DR Document Reader Imaging Guide ...
Page 8: ...ii ...
Page 24: ...1 16 ...
Page 30: ...2 6 ...
Page 32: ...3 2 ...
Page 33: ......