ELECTRIC MODULATING PRESSURE REGULATOR (MODUPLUS

®

)

APPLICATION

The V7335A ”5000” series electric modulating regulator 
(Moduplus®), when installed on VK41../VK81.. series gas 
controls, expands their application versatility and provides 
the following extra functions:

Servo pressure regulation
Outlet pressure is held at a constant value regardless of 
fluctuations of input pressure.

Modulating control
Between minimum and maximum outlet pressure gas 
supply to the appliance is dependent on the electrical 
signal to modulating coil.

Mechanical limitation of outlet pressure
The minimum and maximum burner pressures are 
mechanically adjusted to guarantee good burner 
performance in case the modulating control should 
become out of range.

The Moduplus® is designed to work together with the W4115 
logic control, T7335A thermistor temperature sensor and an 
advanced range of micro computer based modulating 
controls.

SPECIFICATIONS

In general the specifications of the VK41../VK81.. gas 
controls are valid. See instruction sheet EN1R-9162
However the following information is deviating and replaces 
therefore the relevant information of that instruction sheet.

Model

Gas controls:
Suffix M: fast opening with electric modulating regulator.
Suffix N: slow opening with electric modulating regulator.

Electric modulating regulator: 
V7335A low voltage (Moduplus®)

Adjustment points and dimensions

See fig. 1 page 3

Regulator outlet pressure range

See table 1. page 1

Electrical rating

See table 2 page 2

Electrical connection

The Moduplus®  is provided with quick connect 2.8 x 0.8 mm 
terminals which are suitable for appropiate receptacles.

Pressure feedback connection

The Moduplus® has a nipple with 6 mm outer diameter for 
connection between regulator and combustion chamber of 
appliance.

Maximum operating pressure

The P

max.

 indication on the housing of the gas control is the 

maximum pressure at which the gas control functions safely.
However the maximum operating pressure is limited by the 
pressure range of the Moduplus® concerned.
60 mbar for pressure range 1 ... 25mbar / 1 ... 37 mbar

Table 1. Outlet pressure range

Pressure  

range (mbar)

Setting outlet pressure range (mbar)

Minimum Maximum

1 ... 25

1 ... 12

(min s 5) ... 25

1 ... 37

1 ... 25

(min s 5) ... 37

Summary of Contents for 5000 Series

Page 1: ...f the VK41 VK81 gas controls are valid See instruction sheet EN1R 9162 However the following information is deviating and replaces therefore the relevant information of that instruction sheet Model Gas controls Suffix M fast opening with electric modulating regulator Suffix N slow opening with electric modulating regulator Electric modulating regulator V7335A low voltage Moduplus Adjustment points...

Page 2: ...ise to decrease pressure until the desired maximum outlet pressure is obtained Release shaft Check minimum pressure setting and readjust if necessary according instructions below Mount cap and reconnect pressure feedback connection if applicable If minimum and maximum pressures are set wire the Moduplus in circuit Close pressure tap screw Methode 2 Disconnect pressure feedback connection if applic...

Page 3: ...sure gauge Make sure Moduplus is wired in the circuit Start system in fixed setting mode Adjust current as low as needed to obtain the lowest pressure by using pressure setting means of control Mechanical setting of Moduplus will prevent too low setting Close pressure tap screw Increase the current until desired pressure is obtained by using pressure setting means of modulating control Mount cap a...

Page 4: ...ack connection if applicable Remove old Moduplus regulator and discard gasket Place new gasket at the bottom side of Moduplus Orientation of the gasket must be as indicated in figure 3 Push gasket over the small bosses A so that the bosses show fully through the gasket Mount Moduplus on the gas valves The electrical connectors of the Moduplus coil must face the coil of the gas valve see fig 2 The ...