background image

6

FINAL INSTALLATION

Figure 4.2

Figure 5.2

Figure 4.1

Figure 5.1

Figure 4.3

Figure 5.3

Mounting 

Bracket Screw

Canopy Cover

Closemount 

Screw

Mounting 

Bracket

Canopy

Canopy

Canopy

Receiver

Hook

CLOSEMOUNT INSTRUCTIONS

 (optional)

1. Remove the canopy cover from the bottom of the canopy (Figure 4.1). 

2. Remove the three Phillips-head closemount screws from the top of the motor assembly. Then align the canopy with the holes 

in the top of the motor assembly. The larger holes in the canopy will encompass the remaining screws. Secure the canopy to 

the top of the motor assembly with the previously removed closemount screws (Figure 4.2).

3. Raise the motor assembly and place the canopy on the hook of the mounting bracket to free hands during the wiring process 

(Figure 4.3). Then, insert the receiver into the opening of the mounting bracket. 

Mounting 

Bracket Screw

WARNING:

 Do NOT wire the  

fan motor to a variable-speed 

(dimmer) wall control. 

1. Use wire connnectors to connect household supply and fan wires according to the diagram (Figure 5.1) and the following 

steps:

    

 • Connect the green wire from the downrod and mounting bracket to the Bare/Green (ground) supply wire. 

Note: 

Closemount 

installation does not use the downrod, so there will only be two Green wires to connect. 

    

 • Connect the White wire with red label from the receiver to the White (neutral) supply wire.

     

• Connect the Red wire with red label from the receiver to the Black (hot/power) supply wire.

 

     • Connect the Black wire with white label from the receiver to the Black fan wire.

     • Connect the Blue wire with white label from the receiver to the Blue fan wire.

     • Connect the White wire with white label from the receiver to the White fan wire.

2. Align the canopy over the loosened mounting bracket screws. Place the J-slot of the canopy onto the mount bracket screws 

and rotate clockwise (Figure 5.2).

3. Secure the canopy with the two previously removed mounting bracket screws. Tighten all the mounting bracket screws 

securely (Figure 5.3). 

Wire 

Connector

Black (hot/power)

White (neutral)

Bare/Green

(ground)

Red

Whit

e

White

Whit

e

Blac

k

Blue

Blue

Black

Gree

n

Green

Receive

r

Summary of Contents for 50608

Page 1: ...Xerxes Ceiling Fan User Guide Model 50608 50609 Home ...

Page 2: ...Blade Arm x 8 Blade x 8 Yoke Cover Set Screw x 2 Yoke Closemount Screw x 3 Motor Assembly Fitter Plate Fitter Plate Screw x 3 Light Kit Lens Cover Remote Kit Blade Balancing Kit Blade Screw x 24 Screw Cap x 24 Wire Connector x 1 Note Some extra hardware may be included The quantity listed above is the number required for installation ...

Page 3: ...larger than 12 gauge and or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use WARNING To reduce the risk of fire electric shock or personal injury do not bend the blade arms when installing them balancing the blades or cleaning the fan Do not insert objects between the rotating fan blades WARNING To reduce the r...

Page 4: ...egrees Flushmount Installation not available for this model Closemount Installation best suited for ceilings 8 feet or lower 3 Choose a suitable location Ensure the blades will be at least 30 inches from any obstructions Also check the downrod length to ensure the blades will be at least 7 feet above the floor Figure 1 3 1 Loosen all four mounting bracket screws and completely remove the two screw...

Page 5: ... downrod measure 8 inches of wire Cut off the excess wire using wire cutters not included Then strip 1 2 inch of insulation from the end of each wire strand Figure 3 4 5 Install the ball end of the downrod into the opening of the mounting bracket Figure 3 5 WARNING Failure to align the slot in the ball with the tap on the mounting bracket may cause the fan to fall which could result in injury or d...

Page 6: ...o connect household supply and fan wires according to the diagram Figure 5 1 and the following steps Connect the green wire from the downrod and mounting bracket to the Bare Green ground supply wire Note Closemount installation does not use the downrod so there will only be two Green wires to connect Connect the White wire with red label from the receiver to the White neutral supply wire Connect t...

Page 7: ... the single pin connector from the fitter plate to the single pin connector from the light kit Blue to Black and White to White Align the slotted holes in the light kit with the loosened screws in the fitter plate Turn light kit clockwise and replace the previously removed fitter plate screw Tighten all screws Figure 5 6 7 Attach the lens cover to the light kit by twisting the lens cover tightly i...

Page 8: ...l to dim or brighten the lights Non dimmable Bulbs Turns the lights on and off Note The dimmer function does not work with CFL bulbs F D CFL Switch Switch should be set to D to correspond with the included LED bulbs which will enable the dimming function Flip to CFL if you change to non dimmable bulbs Figure 6 1 2 Use the reverse switch located on the top of the motor assembly to optimize your fan...

Page 9: ...ttons on the remote at the same time for 5 seconds The LED indicator will flash 3 times signaling a successful synchronization Once complete the fan will start on the low speed with the light if applicable off 2 Insert new 12V battery in battery compartment of the remote 3 If there are several remote fans in close proximity turn the power off to those fans and re sync the fan 1 Check and tighten a...

Page 10: ...itation of incidental or consequential damages so this limitation may not apply to you If the original purchaser ceases to own the fan this warranty is voided Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part HKC agrees to replace the defective part without charge or at its option to r...

Reviews: