Stand alone programming mode

 (only readers with keypad) 

 

To program in this mode, only the operating voltage is required. 

7.1

Activate programming mode 

Press  the  3  keys  (with  the  symbols  as  shown)  simultaneously  and  keep 
pressed. 

Apply  the  operating  voltage.  As  soon  as  the  programming  mode  is 
activated, the three LEDs flash every second. Release keys.

i

1

2

X

4

5

7.2

Clear address

Activate 

to clear an already allocated address.

7.3

Load standard values 

Activate 

to create the condition on delivery. 

-

Illumination: deactivated for the non load status

An already allocated address is not altered.

7.4

Keypad lighting

If you require permanent illumination, the brightness for the no-load status can be set in steps 
using button "4" and "5". 

Key "4":

Every time the button is activated, the illumination becomes gradually darker until 
it is fully switched off.

Key "5":

The brightness increases in steps until it reaches maximum brightness.
The set value is permanently saved when the programming mode is exited.

7.5

Exit programming mode 

Áctivate 

 

key.

Please note!

The settings of the parameters can be modified via the RS-485 interface of a connected 
controller. 

It  is  not  possible  to  make  any  changes  of  the  parameters  via  Clock/Data  (as  it  is  only 
unidirectional). In this case it is necessary to make a "stand alone" programming.

Mounting and Connection Instructions mifare/DESFire EV1 reader "Accentic" with/without keypad

Summary of Contents for Accentic

Page 1: ...elle mit Tastatur Art Nr 026423 ohne Tastatur Art Nr 026422 mifare DESFire EV1 Leser Accentic RS 485 Schnittstelle mit Tastatur Art Nr 026436 10 ohne Tastatur Art Nr 026435 10 P30715 10 002 15 2014 04 09 Änderungen vorbehalten Klasse C für ZKA und EMA Anerkennungen siehe Kap 10 D GB ...

Page 2: ...chten Die Geräte dürfen nicht in explosionsgefährdeter Umgebung oder in Räumen mit metall und kunststoffzersetzenden Dämpfen eingesetzt werden Inhaltsverzeichnis Seite 1 Anwendung 3 2 Schnittstellen 3 3 Funktionsbeschreibung 4 3 1 mifare allgemein 4 3 2 mifare DESFire EV1 Leser 4 3 2 1 Sicherheitsniveau 4 3 2 2 Datenträger 4 3 2 3 Systemvoraussetzungen 4 4 Montage 5 5 Anschlussplan 6 5 1 Schnittst...

Page 3: ... enorme Sicherheitssteigerung durch Verschlüsse lungsverfahren AES Advanced Encryption Standard Details siehe Kap 3 2 Synchronisation von bis zu 4 dicht nebeneinander montierten Lesern möglich Geringe Stromaufnahme Besonderheiten der Tastatur Länderneutrale Beschriftung der LEDs und der Tastatur Abriebfeste 10er Komforttastatur mit 6 zusätzlichen Funktionstasten Taktile und akustische Rückmeldung ...

Page 4: ... der DESFire EV1 Leser verwendet einen 128 Bit Schlüssel Das Verschlüsselungsverfahren AES gilt als extrem abhör und manipulationssicher und ist in den USA für staatliche Dokumente mit höchster Geheimhaltungsstufe zugelassen 3 2 2 Datenträger Um das Verschlüsselungsverfahren AES nutzen zu können werden mifare DESFire EV1 Daten träger benötigt Weitere Informationen entnehmen Sie bitte unserem aktue...

Page 5: ...In Holz je nach Sorte Halbrund Holzschraube mit Schlitz 3 5 x 45 bis 3 5 x 60 mm In Metall Zylinderkopfschraube M3 x 30 mm min mit Unterlegscheibe Auf der Standard uP Dose Halbrund Holzschraube mit Schlitz 3 0 x 40 mm und Unterleg scheibe Zur weiteren Befestigung kann bei Bedarf die dritte Montagebohrung verwendet werden Die Schraubenlänge muss ebenfalls dem Montageuntergrund angepasst werden Bei ...

Page 6: ...ere Funktion ist zu beachten dass das 6 m lange Anschlusskabel auf max 200 m verlängert werden darf Voraussetzung keine externe Störspannung Zur Verlängerung kann z B ein Kabel der Ausführung JY ST Y 6x2x0 6 mm DIN VDE 0815 Verwendung finden Speziell für Prüf und Vormontageaufbauten sind am Kabel des Lesers werkseitig Stecker angelötet Für die endgültige Installation müssen sie in der Regel abgesc...

Page 7: ...r sind inaktiv geschaltet Nach einer Nachlaufzeit von ca 5 Sek sind sie wieder bereit Leser 1 Leser 2 Leser 3 sw sw sw max 4 Leitung für die Synchronisation 6 Inbetriebnahme und Konfiguration 6 1 Wichtige Informationen zur Verwendung von Datenträgern X Der Datenträger sollte etwa mittig in dieses Feld gehalten werden Halten Sie ausschließlich den gewünschten Datenträger in das Lesefeld Montage Ans...

Page 8: ...ers wird der Vorgang gestartet Die Adresse wird automatisch vergeben und anschließend im Leser abgespeichert Solange der Adressvergabemodus aktiv ist können auf diese Weise mehrere Leser nacheinander auto matisch mit Adressen versehen werden Empfehlung Geeignet bei kleineren Entfernungen zwischen Zentrale und den einzelnen Lesern 3 Manuell über Lesertastatur siehe 6 2 6 Nur möglich bei Lesern mit ...

Page 9: ...r Kontrolle neu ange legter Adressen und der späteren Kontrolle Zehnerstelle obere LED grün Jedes Blinken zeigt die Zehnerstelle der verge benen Adresse an Beispiel 2 x blinken 20 Einerstelle mittlere LED gelb Jedes Blinken zeigt die Einerstelle der vergebenen Adresse an Beispiel 4 x blinken 4 Im Anschluss daran wird wieder der Adressvergabemodus durch die untere LED angezeigt Adressenanzeige wied...

Page 10: ... Adresse ändern Neue Adresse 1 oder 2 stellig eingegeben und mit OK bestätigen Quittierung und Anzeige wie oben Alle zugeordneten Parameter werden von der alten zur neuen Adresse übertragen und die alte Adresse wird wieder frei Adressvergabe m 2 3 6 5 4 7 8 9 0 r 1 Löschen Verwerfen Bestätigung OK 6 2 5 utomatisch mit Der Adressvergabemodus muss aktiviert sein Beliebigen mifare Datenträger in den ...

Page 11: ...iebsspannung anlegen danach Tasten loslassen Die Adresse ist jetzt gelöscht Hinweis Wird der Leser später mit der AWE Zentrale verbunden so wird die eingegebene Adresse zusammen mit der Leser Seriennummer zur AWE Zentrale gesendet und dort abge speichert Im Anzeigemodus siehe 6 2 3 kann jetzt die Adresse überprüft werden 6 2 8 Adresse n löschen Über die Programmierung oder im stand alone Betrieb s...

Page 12: ...chaltet Eine bereits vergebene Adresse bleibt erhalten 7 4 Tastatur Hintergrundbeleuchtung Die Helligkeit der Hintergrundbeleuchtung für den Ruhezustand kann mit den Tasten 4 und 5 stufen weise eingestellt werden Taste Beginnend mit der vollen Helligkeit wird bei jeder Betätigung der Taste die Beleuchtung stufenweise dunkler bis sie ganz abgeschaltet ist Taste Die Helligkeit wird stufenweise erhöh...

Page 13: ...ann nur bei Verwendung von ID Datenträgern aus unserem Haus garantiert werden Die Geräte mifare Leser Accentic mit Tastatur Art Nr 026423 mifare Leser Accentic ohne Tastatur Art Nr 026422 mifare DESFire EV1 Leser Accentic mit Tastatur Art Nr 026436 10 mifare DESFire EV1 Leser Accentic ohne Tastatur Art Nr 026435 10 entsprechen bei bestimmungsgemäßer Anwendung den grundlegenden Anforderungen gemäß ...

Page 14: ...ktop Reader mifare Classic DESFire zwingend erforderlich 12 Reinigung und Pflege Gehäuse und Tastatur Das Gehäuse und dieTastatur können bei Bedarf mit einem weichenTuch gereinigt werden Bei starker Verschmutzung können Sie ein mit Wasser angefeuchtetesTuch benutzen Verwenden Sie keine Reinigungsmittel Scheuermittel oder Lösungsmittel wie Spiritus Alkohol oder Benzin Montage Anschluss Anleitung mi...

Page 15: ...Notizen 15 Montage Anschluss Anleitung mifare DESFire EV1 Leser Accentic mit ohne Tastatur ...

Page 16: ...Honeywell Security Group Novar GmbH Johannes Mauthe Straße 14 D 72458 Albstadt www honeywell com security de P30715 10 002 15 2014 04 09 2014 Novar GmbH ...

Page 17: ...85 and Clock Data interface with keypad Item no 026423 without keypad Item no 026422 mifare DESFire EV1 reader Accentic RS 485 interface with keypad Item no 026436 10 without keypad Item no 026435 10 Subject to change without notice D GB P30715 10 002 15 2014 04 09 ...

Page 18: ...eypad lighting 28 7 5 Exit programming mode 28 8 LED indication 29 9 Technical data 29 10 VdS approvals 30 11 Accessories 30 12 Cleaning and care 30 13 FCC Statements 31 Safety notes Read the instructions carefully and thoroughly before installing the device and putting it into operation They contain important information on assembly programming and operation The device is a state of the art produ...

Page 19: ...coustical acknowledgement Night design with time limited luminous background 1 Application The mifare readers Accentic and mifare DESFire EV1 readers Accentic are used in intrusion detection systems and access control systems as reading units and operating units The mifare readers features different interfaces see Chapter 2 offering a wide spectrum of applications 2 Interfaces mifare readers 02642...

Page 20: ...cryption Standard The current encoding procedure AES of DESFire EV1 readers uses a 128 bit key The encoding procedure AES is known as extremely tap proof and tamper resistant In th USA it is approved for government documents in the highest security ratings 3 2 2 Data carriers To be able to use the encryption AES mifare DESFire EV1 data carriers are needed For further information refer to our curre...

Page 21: ...nding on type Semi circular wood screw with slot 3 5 x 45 to 3 5 x 60 mm In metal Fillister head screw M3 x 30 mm min with washer On the standard s m socket Semi circular wood screw with slot 3 0 x 40 mm and washer For additional fixing the third borehole can be used Choose the correct screw length for the mounting surface When mounting feed the connecting cable if possible from the back through a...

Page 22: ...stalled in front of the reader For further information refer to the description of the corresponding controller Clock Data To ensure reliable functioning ensure that a possible extension of the 6 m connecting cable does not exceed 200 m Condition no external interference voltage A JY ST Y 6x2x0 6 mm cable DIN VDE 0815 can be used for extension purposes F i 2 3 6 5 4 7 8 9 3 0 r 1 U_b 9 V to 30 V D...

Page 23: ...data carrier is held separately in the reading range black Synchronization line Reader 1 Reader 2 Reader 3 max 4 black black 5 2 Synchronization In order to prevent densely packed readers from affecting one another they must be connected to one another via the Synchronization line black Up to 4 readers can be synchronized in this manner irrespective of the used interface Synchronization is require...

Page 24: ...he reading area of the reader The address is allocated automatically and then stored in the reader As long as the address allocation mode is active several readers can be automatically allocated addresses in succession Recommendation Suitable for shorter distances between the central control unit and the individual readers Manual input of the serial numbers of the readers is not required 3 Manuall...

Page 25: ...e is then displayed in the lower LED Repeat indication of addresses Hold the data carrier briefly in the reading range of the reader A brief acoustical acknowledgement confirms the request to indicate and restarts the indication sequence The bottom LED remains dark when the address is indicated Tens digit green Units digit yellow This example shows address 24 6 2 4 Manual address allocation via ce...

Page 26: ... can be allocated to an reader on site The plausibility check in the controller prevents an address from being allocated more than once Note Every activated key is acknowledged by a click An address entry can be rejected by an X Enter the new address with 1 or 2 digits and acknowledge with OK key The address is transmitted to the controller and checked Positive acknowledgement After remaining blan...

Page 27: ...hen the keys 1 7 and X are pressed simultaneously and keep pressed whilst the operating voltage is re applied An address can also be deleted in the programming mode Stand alone see 7 2 Note If the reader is connected at a later stage to the controller the entered address is transmitted together with the serial number of the reader to the controller and stored 6 2 8 Clear addresses Via programming ...

Page 28: ...pad lighting If you require permanent illumination the brightness for the no load status can be set in steps using button 4 and 5 Key 4 Every time the button is activated the illumination becomes gradually darker until it is fully switched off Key 5 The brightness increases in steps until it reaches maximum brightness The set value is permanently saved when the programming mode is exited 7 5 Exit ...

Page 29: ...imensions W x H x D 75 x 142 x 32 mm Colour White aluminium similar to RAL 9006 1 The denoted reading distance can only be garanteed by using data carriers provided by our company The following readers mifare reader Accentic with keypad Item no 026423 mifare reader Accentic without keypad Item no 026422 mifare DESFire EV1 reader Accentic with keypad Item no 026436 10 mifare DESFire EV1 reader Acce...

Page 30: ... DESFire EV1 data carriers 026487 USB Desktop reader mifare Classic DESFire mandatory 12 Cleaning and care Housing and keypad The housing and keypad can be cleaned when necessary with a soft cloth Use a cloth moistened by water if heavily soiled Do not use cleaning agents abrasives or solvents such as spirits alcohol or petrol 10 VdS approvals 026422 mifare reader w o keypad Z107003 ACS Class C G1...

Page 31: ...ss B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that ...

Page 32: ...Honeywell Security Group Novar GmbH Johannes Mauthe Straße 14 D 72458 Albstadt www honeywell com security de P30715 10 002 15 2014 04 09 2014 Novar GmbH ...

Reviews: