29
8.
LED indication
yellow
green
red/green
9.
Technical data
Rated operating voltage
12 V / 24 V DC
Operating voltage range
9 V to 30 V DC
Current consumption in stand by mode <30 mA (on average)
Time-limited write/read mode
<55 mA (incl. status indication)
(Time lag after last data carrier reactivation 5 sec.)
Luminous background
<4 mA (time-limited for 5 sec. max. 8 mA)
Brightness settable
Mounting surface
Any surface, also metal
1)
Reading distance
- mifare readers
>4 cm up to 8 cm, depending on data carrier typ
and mounting site- /surroundings Interfaces
- mifare DESFire EV1 readers
aprox. 1.5 cm (only cards)
Interface range:
- RS-485
up to 1200 m
- Clock/Data
up to 200 m
Connecting cable
12-core (5-core DESFire EV1 reader), shielded, length 6 m
Protection category as per
IP 65
Environmental class as per VdS
III
Operating temperature range
-25 °C to +55 °C
Housing dimensions (W x H x D)
75 x 142 x 32 mm
Colour
White aluminium (similar to RAL 9006)
1)
The denoted reading distance can only be garanteed by using data carriers provided by our
company.
The following readers
- mifare reader "Accentic" with keypad Item no. 026423
- mifare reader "Accentic" without keypad Item no. 026422
- mifare DESFire EV1 reader "Accentic" with keypad Item no. 026436.10
- mifare DESFire EV1 reader "Accentic" without keypad Item no. 026435.10
comply with the essential requirements of the R&TTE 1999/5/EC Directive, if used for
its intended use.
The EC-Declaration of Conformity can be downloaded from our homepage (Service / Download).
info.security.de@honeywell.com
EN 60529
The LEDs will be driven by the connected controller. Depending on the
connected controller the functions are fixed or can be defined via the
programming.
Special case: the LED below flashes red and green alternating.
This means a system error. In this case you should contact our support.
Mounting and Connection Instructions mifare/DESFire EV1 reader "Accentic" with/without keypad