ACUIX IP Rugged Housing and Dome Installation Guide
Document 800-02460 Rev A
11
08/08
Related Documents
Table 1-1
Related Documents and External Links
Wiring and Power Cautions and Requirements
Wiring and Power Cautions
Document title or link
Part number
ACUIX IP High Speed Digital Dome User Guide
800-00336
ACUIX IP Quick Installation Guide
800-00020
Honeywell Video online literature
http://www.honeywellvideo.com/support/literature/index.html
Access PDF versions of data sheets, quick references, installation and user guides,
specifications, product notices and other useful material
•
To make good wire contact and ensure the wire does not short to adjacent
wires, fully insert the wire in the hole on the terminal strip.
•
A good earth ground must be connected at J1, pin 2. Surge suppression is not
provided if the unit is not connected to a good earth ground.
•
Ensure there are no bare wires touching or faulty operation may occur.
•
Ensure the cabling does not interfere with the rotation of the pan and tilt
assembly.
•
To maintain 24 VAC ± 10% at each dome, the proper wire size for the distance
and the number of domes must be determined.
•
For CE compliance, the power supply must be connected to a CE approved
240V UPS (uninterruptible power supply). See
for a list of the power
supplies which must be used to meet FCC and UL requirements.