LXL-1010 Installation and Setup Guide
4–6
Output and System Setup (*77 - *93)
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*77
Daylight Saving Time
Start/End Month
0 = Disabled
4 = April
1 = Jan
# + 10 = Oct
2 = Feb
# + 11 = Nov
3 = Mar
# + 12 = Dec
Enter the start and end month for daylight savings time, if
applicable to the region.
*78
Daylight Saving Time
Start/End Weekend
0 = disabled
4 = fourth
1 = first
5 = last
2 = second
6 = next to last
3 = third
7 = third to last
Enter the start and end weekend for daylight savings time, if
applicable to the region.
*79
Output Device Mapping Menu Mode
Use this menu mode to enter powerline carrier devices into the
system. See Output Device Programming section for procedures.
*80
Output Programming Menu Mode
Use this menu mode to define output functions for use with
output powerline carrier devices. See Output Programming
section for procedures.
*81
Zone List Programming Menu Mode
Use the menu mode to define zone lists. See Zone List
Programming section.
*82
Alpha Descriptor Programming
Menu Mode
Use this menu mode to assign alpha descriptors.
*84
Auto-Stay Arm
0 = no
1 =yes
When this field is enabled, if the system is armed in AWAY
mode at a keypad, it will automatically reverts to armed STAY
mode if a door is not opened and shut within the programmed
exit delay time (if armed MAXIMUM it will revert to INSTANT).
An Opening report followed by an Armed Stay report is sent to
the Central Station. Any RF keyfob that arms the system AWAY
overrides this feature and the system remains armed in the
AWAY mode.
*85
Cross Zone Timer
(in seconds)
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
#+13 = 10 min
2 = 45 secs
8 = 4 min
#+14 = 12 min
3 = 60 secs
9 = 5 min
#+15 = 15 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Sets the maximum amount of time in which two cross zones
must be tripped in an armed system to send an alarm message
to the Central Station. If only one cross zone is tripped during
this time, a trouble message (CID code 380) for that zone is sent
to the Central Station.
Assign cross zone pairs in zone list 4.
This option not for use in UL installations.
*86
Cancel Verify Keypad Display
0 = no
1 = yes
When enabled (1 = yes), this feature causes a “
CANCELED
ALARM”
display on the LCD keypad under the following
conditions:
•
After the kissoff of the cancel message to the Central Station,
indicating a successful transmission.
•
When an alarm is successfully canceled before the Central
Station received the Alarm message. E.g., if an alarm is
incorrectly triggered and the user presses code + OFF before
the dial delay time has expired, the message will never go out
to the CS.
•
When the Cancel report is not enabled and the system is
disarmed:
a.
before
dialer delay expires (alarm report not sent)
message “Canceled Alarm” is displayed.
b.
after
dialer delay expires message “Canceled Alarm” is not
displayed.
*87
Misc. Fault Delay Time
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
#+13 = 10 min
2 = 45 secs
8 = 4 min
#+14 = 12 min
3 = 60 secs
9 = 5 min
#+15 = 15 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Used with zones assigned to a configurable zone type with fault
delay on (configurable zone type digit “6”), and sets a zone
response time of 15 seconds to 15 min. It can be assigned to
zones with sensors that provide a trouble indication when an oil
tank is low, or similar applications for critical condition
monitoring where a non-alarm response is desired.
UL: May only be used on non-burglar alarm and non-fire alarm
zones when used on a fire and/or UL burglar alarm installation.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for ADEMCO LYNX XL Series
Page 8: ...LXL 1010 Installation and Setup Guide 1 4 www PDF Zoo com firealarmresources com ...
Page 18: ...LXL 1010 Installation and Setup Guide 2 10 www PDF Zoo com firealarmresources com ...
Page 44: ...LXL 1010 Installation and Setup Guide 6 2 www PDF Zoo com firealarmresources com ...
Page 50: ...LXL 1010 Installation and Setup Guide 8 2 www PDF Zoo com firealarmresources com ...
Page 60: ...LXL 1010 Installation and Setup Guide 11 4 www PDF Zoo com firealarmresources com ...
Page 66: ...LXL 1010 Installation and Setup Guide 12 6 www PDF Zoo com firealarmresources com ...
Page 70: ...LXL 1010 Installation and Setup Guide 13 4 www PDF Zoo com firealarmresources com ...
Page 74: ...LXL 1010 Installation and Setup Guide 14 4 www PDF Zoo com firealarmresources com ...